these cables are pictured in orange and green (which appear darker if viewed in black and white). In each case cables run from the disk contrl ports to the in ports of the SBOD card. A
second expansion enclosure has been added by running cables from the out ports on the first expansion enclosure to the in ports on the second expansion enclosure. At the bottom of the diagram, dotted lines indicate the potential cabling to add more expansion enclosures to that loop
Cables attach to server enclosure
disk contrl ports
First expansion enclosure on loop 1 (first enclosure
on loop)
Second expansion enclosure on loop 1
(second enclosure on loop)
Figure 2-15 Expansion enclosure cabling (Disk Contrl ports on loop 1)
2.7 Front panel
The DS6000 front operator panel allows you to perform a health check with a single glance. There are 7 indicators present on the panel; they are depicted in Figure
System power
System identify
System information
System alert
Data in cache on battery
CRU fault on rear
Fault in expansion enclosure
Figure 2-16 DS6000 front panel
Chapter 2. Components 37