Figure 2-7 Industry standard FC-AL disk enclosure

The main problems with standard FC-AL access to DDMs are:

￿The full loop is required to participate in data transfer. Full discovery of the loop via LIP (loop initialization protocol) is required before any data transfer. Loop stability can be affected by DDM failures.

￿In the event of a disk failure, it can be difficult to identify the cause of a loop breakage, leading to complex problem determination.

￿There is a performance drop off when the number of devices in the loop increases.

￿To expand the loop it is normally necessary to partially open it. If mistakes are made, a complete loop outage can result.

These problems are solved with the switched FC-AL implementation on the DS6000.

Switched FC-AL advantages

The DS6000 uses switched FC-AL technology to link the device adapter (DA) pairs and the DDMs. Switched FC-AL uses the standard FC-AL protocol, but the physical implementation is different. The key features of switched FC-AL technology are:

￿Standard FC-AL communication protocol from DA to DDMs

￿Direct point-to-point links are established between DA and DDM

￿Isolation capabilities in case of DDM failures, which provides easy problem determination

￿Predictive failure statistics

￿Simplified expansion: no cable rerouting required when adding another disk enclosure

The DS6000 architecture employs dual redundant switched FC-AL access to each of the disk enclosures. The key benefits of doing this are:

￿Two independent switched networks to access the disk enclosures

￿Four access paths to each DDM

￿Each device adapter port operates independently

￿Double the bandwidth over traditional FC-AL loop implementations

In the DS6000, the switch chipset is completely integrated into the controllers. Each controller contains one switch. Note, however, that the switch chipset itself is completely separate from the controller chipset. In Figure 2-8 on page 31 each DDM is depicted as being attached to two separate Fibre Channel switches. This means that with two RAID controllers, we have four effective data paths to each disk, each path operating at 2Gb/sec.

30DS6000 Series: Concepts and Architecture

Page 54
Image 54
IBM DS6000 Series manual Switched FC-AL advantages, Industry standard FC-AL disk enclosure