A logic or power failure in a SAN switch can interrupt communication between hosts and the DS6800. We recommend that more than one SAN switch be provided to ensure continued availability. For example, four of the eight fibre ports in a DS6800 could be configured to go through each of two directors. The complete failure of either director leaves half of the paths still operating.
Multipathing software
For each attached host we now require a mechanism to allow the attached operating system to manage multiple paths to the same device, and to also show a preference in this routing so that I/O requests for each LUN go to the preferred controller. Also, when a controller failover occurs, attached hosts that were routing all I/O for a particular group of LUNs (LUNs on either even or odd LSSs) to a particular controller (because it was the preferred controller) must have a mechanism to allow them to detect that the preferred path is gone. It should then be able to
3.2.1 Open systems host connection
In the majority of open systems environments, IBM recommends the use of the Subsystem Device Driver (SDD) to manage both path failover and preferred path determination. SDD is supplied free of charge to all IBM customers who use ESS 2105, SAN Volume Controller (SVC), DS6800, or DS8000. A new version of SDD (Version 1.6) will also allow SDD to manage pathing to the DS6800 and DS8000.
SDD provides availability through automatic I/O path failover. If a failure occurs in the data path between the host and the DS6800, SDD automatically switches the I/O to another path. SDD will also set the failed path back online after a repair is made. SDD also improves performance by sharing I/O operations to a common disk over multiple active paths to distribute and balance the I/O workload. SDD also supports the concept of preferred path.
SDD is not available for all supported operating systems, so attention should be directed to the IBM TotalStorage DS6000 Host Systems Attachment Guide,
http://www.ibm.com/servers/storage/disk/ds6000/interop.html
3.2.2 zSeries host connection
In the zSeries environment, the normal practice is to provide multiple paths from each host to a disk subsystem. Typically, four paths are installed. The channels in each host that can access each Logical Control Unit (LCU) in the DS6800 are defined in the HCD (or IOCDS) for that host. Dynamic Path Selection (DPS) allows the channel subsystem to select any available
These functions are part of the zSeries architecture and are managed by the channel subsystem in the host and the DS6800.
Chapter 3. RAS 51