Select and run the diagnostic tests on the resources you are having problems with or select the All Resources option to check all of the configured resources. Find the response in the following table and follow the instructions given in the Action column.

Diagnostic Response

Action

 

 

An SRN is displayed.

Go to ªStep 14º.

 

 

The system hangs.

Report SRN 109-200.

 

 

The Testing Complete menu and the No

Press Enter and continue with the testing.

trouble was found message is displayed, and

 

you have not tested all of the resources.

 

 

 

The Testing Complete menu and the No

Go to ªStep 17º on page 155.

trouble was found message displayed and you

 

have tested all of the resources.

 

 

 

Step 14

The diagnostics produced an SRN for this problem. Do the following:

1.Record the SRN and other numbers read out.

2.Report the SRN to the service organization.

3.STOP. You have completed these procedures.

Step 15

When you are loading the Stand-alone Diagnostics, the attributes for the terminal must be set to match the defaults of the diagnostic programs. The ASCII terminal must be attached to serial port 1 on the system unit.

Are you going to load Stand-alone Diagnostics and run them from a ASCII terminal?

NO

Go to ªStep 16º.

YES

Go to ªRunning Diagnostics from a TTY Terminalº on page 109. and

 

be sure your terminal attributes are set to work with the diagnostic

 

programs.

 

Return to ªStep 16º when you finish checking the attributes. Record

 

any settings that are changed.

Step 16

This step loads the Stand-alone Diagnostics. If you are unable to load the diagnostics, go to ªStep 7º on page 151.

1.Turn the power on.

2.Insert the diagnostic CD-ROM into the CD-ROM drive.

3.When the keyboard indicator displays, press F5 on the directly attached keyboard, or 5 on the ASCII keyboard, to indicate that diagnostics are to be loaded.

15444P Series Model 170 User's Guide

Page 172
Image 172
IBM RS/6000 44P manual Diagnostic Response Action