IBM RS/6000 44P manual Symptom Action

Models: RS/6000 44P

1 216
Download 216 pages 24.35 Kb
Page 176
Image 176

Symptom

Action

 

 

The diskette LED is blinking rapidly, or E1EA or

The flash EPROM data is corrupted. Run the

E1EB is displayed on the operator panel.

recovery procedure for the flash EPROM.

 

 

The system stops with a prompt to enter a

Enter the password. You are not allowed to

password.

continue until a correct password has been

 

entered. When you have entered a valid

 

password, wait for one of the other conditions

 

to occur.

 

 

The system stops with an eight-digit error

Record the error code(s) and report the

code(s) displayed on the console.

problem to the service organization.

 

 

The system login prompt is displayed.

You may not have pressed the correct key, or

 

you may not have pressed the key soon

 

enough when you were to indicate a Service

 

Mode boot of diagnostic programs. If this was

 

the case, start over at the beginning of this

 

step.

 

If you are sure you pressed the correct key in a

 

timely manner go to Step 7.

 

 

The system does not respond when the

Go to Step 7.

password is entered.

 

 

 

The system stopped and an indicator is

If the indicator (text or icon) represents:

displayed on the system console and an

v A keyboard, record error code M0KBD000

eight-digit error code is not displayed.

and report the problem to the service

 

 

organization.

 

v Memory, record error code M0MEM002 and

 

report the problem to the service

 

organization.

 

v SCSI, record error code M0CON000 and

 

report the problem to the service

 

organization.

 

v Network, record error code M0NET000 and

 

report the problem to the service

 

organization.

 

v Speaker/Audio, record error code M0BT0000

 

and report the problem to the service

 

organization.

 

 

15844P Series Model 170 User's Guide

Page 176
Image 176
IBM RS/6000 44P manual Symptom Action