Croma24 Service Manual

e.Turn the Carrier Assembly over and insert the Paper Sensor flex cable into the connector at J3.

f.Push both sides of the connector lock shut at the same time.

2.To install the Encoder Sensor:

a.Turn the Carrier Assembly so that the bottom side of it is facing up.

b.Push down on the plastic clip and slide the back of the Encoder Sensor over it.

c.Push the Encoder Sensor in past the ridges until the Encoder Sensor snaps into place.

d.Turn the Carrier Assembly over and insert the Encoder flex cable into the connector at J2.

e.Push both sides of the connector lock shut at the same time.

3.Perform the Carrier Assembly, Carrier Belt, and the Frame Tensioner Reinstallation procedures to reinstall the Carrier Assembly.

Remove the Trailing Cable Cover Assembly

1.Perform the Left, Middle, and Right Cover Removal procedures to remove the Left, Middle and Right Covers.

2.If you have not already removed the Carrier Assembly from the Slide Shaft, you will need to perform Steps 3 through 7 of the Removing the Carrier Assembly, Carrier Belt, and the Frame Tensioner procedures in order to remove the Electronics Cover and release the left end of the Trailing Cable from the Carrier PCB.

3.Disconnect the Ferrite and Ferrite Bracket from the Strain Relief by turning the Strain Relief over and pushing down on the Ferrite Bracket’s catch until it can pass under the Strain Relief. Pull the Ferrite Bracket clear from the Strain Relief.

DISASSEMBLY

ASSEMBLY/

 

 

Assembly\Disassembly 105

Page 105
Image 105
Integra CROMA24 service manual Remove the Trailing Cable Cover Assembly