Croma24 Service Manual

11.Using care, remove the MPCB by bringing it out the front of the printer.

Failure to use an approved anti-static bag for storage or shipment may cause damage to the MPCB and af- fect the Warranty.

12.Place the MPCB in an ESD bag (anti-static bag) in preparation for shipment to ENCAD for replacement or repair, or if it is to be stored at your facility for repair.

Install the MPCB and Actuator Assembly

Integrated circuits may become weakened or damaged by electrical discharge. Do not touch or work near in- tegrated circuits without wearing an ESD wrist strap.

1.Put on an ESD wrist strap.

2.Remove the MPCB from the ESD bag.

3.Insert the MPCB through the area in the front of the printer. Align the MPCB so that the serial and parallel connections protrude out of the back of the printer and that the screw holes are aligned to the holes on the Base of the printer.

4.Using a #2 Phillips Torque Screwdriver, fasten the Actuator Assy to the MPCB and the Base with 15 in-lb of torque.

5.Attach the grounding strap for the Stepper Motor.

DISASSEMBLY

ASSEMBLY/

 

 

Assembly\Disassembly 91

Page 91
Image 91
Integra CROMA24 service manual Install the Mpcb and Actuator Assembly