Croma24 Service Manual
13.Once the Idler Pulley Assembly is in position, pinch the belt to hold the Idler Pulley Assembly in place and pull it into the Frame Tensioner so that the axle rests in the
14.Insert the Compression Spring into the opening in the back of the Frame Tensioner so that the end of the spring fits over the post inside the opening.
15.Fit the Compression Spring over the post at the back of the C- Bracket.
16.Fit the notch in the front end of the Frame Tensioner over the notch in the front of the
17.Depress the back of the Frame Tensioner and slip the Carrier Belt over the Servo Motor pulley. Make sure that the guides in the Carrier Belt are properly fitted over the Servo Motor pulley.
18.Gently move the Carrier Assembly from end to end and make sure that the Carrier Belt is not rubbing against any other parts.
Remove the Carrier PCB
Integrated circuits may become weakened or damaged by electrical discharge. Do not touch or work near integrated circuits without wearing an ESD wrist strap.
1.Perform the Carrier Assembly, Carrier Belt, and the Frame Tensioner Removal procedures to remove the Carrier Assembly from the Slide Shaft.
2.Put on an ESD wrist strap.
3.Unlock the connectors and remove all flex cables on the Carrier PCB. Ensure that the ferrite remains on the black cartridge flex cable.