Croma24 Service Manual
3.Position the Service Station inside the Right Cover and place the left side of the Service Station into the Platen.
4.Push down on the right side of the Service Station until the Service Station snaps into place.
5.Slide the Carrier Assembly to the right and back into the home position.
6.Lower the Middle Cover.
Remove the Lower Roller Assembly and Stepper Motor
1.Perform the Carrier Assembly, Carrier Belt, and the Frame Tensioner Removal procedures to remove the Carrier Assembly from the Slide Shaft.
2.Perform the Trailing Cable Cover Assembly Removal procedures to remove the Trailing Cable Support Assembly.
3.Disconnect the Servo Motor connector (red and blue wires) at the J4 location on the MPCB.
4.Using a #2 Phillips screwdriver, remove the back screw on the Servo Motor. The screwdriver will be at a slight angle. Be careful not to strip the head of the screw or to cause damage to the Encoder Strip.
5.While holding the Servo Motor, remove the front screw on the Servo Motor.
6.Tilt the bottom of the Servo Motor towards the back of the Platen and carefully lower the motor through the opening and out of the back of the