Topology Change

The value of the topology change parameter for the switch indicating if a topology change is in progress on any port on the bridge. It takes a value if True or False.

Designated Root

The bridge identifier of the root bridge.

Root Path Cost

Path Cost to the Designated Root for this bridge instance.

Root Port Port to access the Designated Root.

Max Age (secs)

Path Cost to the Designated Root for this bridge instance.

Forward Delay (secs)

Derived value of the Root Port Bridge Forward Delay parameter.

Hold Time (secs)

Minimum time between transmission of Configuration BPDUs.

CST Regional Root

Priority and base MAC address of the Common Spanning Tree Regional Root.

CST Path Cost

Path Cost to the CST tree Regional Root.

Click the Refresh button to update the screen with the most recent data.

Click the Apply button to update the switch with the values on this screen. If you want the switch to retain the new values across a power cycle you must perform a save.

CST port configuration/status

Use this panel to configure a particular port within the CST.

Port

Select one of the physical or LAG interfaces from the pull-down menu.

Intel® Blade Server Ethernet Switch Module IXM5414E