The IXM5414E switch module supports
Complete the following steps to connect to the switch module through the Telnet interface:
1.Display a window that contains a DOS prompt command line; for example, C:\>.
2.Type the following command on the DOS prompt command line and press Enter: telnet x.x.x.x where x.x.x.x is the IP address for your switch module
When you first connect to the switch module, you will be prompted to enter a user ID followed by a password. Enter USERID in response to the prompt for a user ID and enter PASSW0RD in response to the prompt for a password (notice the use of the zero and not the “O”). This will give you Read/write access to the switch module. By default, the switch module has one
/NOTE
All user IDs and passwords are CASE SENSITIVE.
Only a user with Read/write privileges can add new user accounts or make changes to existing user accounts. Another function available with a Read/write account is updating firmware and configuration files.
Changing configuration settings
The IXM5414E switch module has two levels of memory: normal
/NOTE
Some settings require you to restart the switch before they will take effect. Make sure you save the new configuration to NVRAM first.
There are two ways to change the configuration stored in NVRAM:
•Save a new configuration using the save config command.
•Reset all configuration values to the initial settings listed in Appendix Appendix C