Chapter 4 — Enabling and Configuring Symbologies

Gap Check

Enable---------

Disable---------

END ------------------------------------------

Label Length Format

The following two sections explain how to set the Codabar Label

Length Format to either the Variable Length or Fixed Length

Format.

Variable Length Format

You can set the Codabar symbology to Variable Length Format.

To set the Codabar symbology to Variable Length Format

1Identify the minimum length setting you want to make. The selectable range is 03 to 50 characters.

Note: For this symbology, the scanner decodes up to 50 characters, but the actual length read varies depending upon the interface type, bar code physical size, and print quality.

2Scan the SET bar code.

3Scan the Enable Variable Length Format bar code.

4Scan the Set Minimum Label bar code.

5Using the Digits bar codes on page 97, scan the digits to set the minimum label length you identified in Step 1.

94

SR60 Scanner Programmer’s Reference Manual

Page 106
Image 106
Intermec SR60 manual Label Length Format, To set the Codabar symbology to Variable Length Format