Chapter 4 — Enabling and Configuring Symbologies
•The Enable Standard 2 of 5 bar code on page 70 selects Standard 2 of 5 as an active symbology. Options for this symbology are similar to Interleaved 2 of 5 features.
•The Enable IATA bar code on page 70 selects the IATA custom code (which is a special symbology subset of Standard 2 of 5) as the active Standard 2 of 5 symbology, superseding any other Standard 2 of 5 features.
Note: Standard 2 of 5 must be enabled in order for IATA to be active. However, while IATA is enabled, Standard 2 of 5 is not decoded.
•The Enable MSI/Plessey bar code on page 70 selects MSI/ Plessey as an active symbology. Allows selection of check digit or label format (fixed or variable length) options.
Scan the following bar codes to enable specific symbologies or disable all symbologies.
Note: If you enable a symbology that has additional features that should be set, turn to the pages that support that symbology and its programmable features.
.
SET
Disable All Symbologies
Symbology Selections
Enable Code 39