Chapter 4 — Enabling and Configuring Symbologies
Transmit---------
Code 39 Full ASCII
Enable---------
Disable---------
END ------------------------------------------
Minimum Label Length
The following procedure explains how to set the Code 39
Minimum Label Length.
To set Code 39 Minimum Label Length
1Identify the minimum label length setting you want to make. The selectable range is 00 to 48 characters.
Note: For this symbology, the scanner decodes up to 48 characters, but the actual length read varies depending upon interface type, bar code physical size, and print quality. Code 39 bar codes containing one or more full ASCII characters can also limit the amount of characters that are decoded; in these circumstances, the scanner decodes at least 24 data characters.
2Scan the SET bar code.
SR60 Scanner Programmer’s Reference Manual | 73 |