Intermec SR60 manual To set Code 39 Minimum Label Length, Enabling and Configuring Symbologies

Models: SR60

1 174
Download 174 pages 54.63 Kb
Page 85
Image 85
Code 39 Full ASCII

Chapter 4 — Enabling and Configuring Symbologies

Transmit---------

Code 39 Full ASCII

Enable---------

Disable---------

END ------------------------------------------

Minimum Label Length

The following procedure explains how to set the Code 39

Minimum Label Length.

To set Code 39 Minimum Label Length

1Identify the minimum label length setting you want to make. The selectable range is 00 to 48 characters.

Note: For this symbology, the scanner decodes up to 48 characters, but the actual length read varies depending upon interface type, bar code physical size, and print quality. Code 39 bar codes containing one or more full ASCII characters can also limit the amount of characters that are decoded; in these circumstances, the scanner decodes at least 24 data characters.

2Scan the SET bar code.

SR60 Scanner Programmer’s Reference Manual

73

Page 85
Image 85
Intermec SR60 manual To set Code 39 Minimum Label Length, Enabling and Configuring Symbologies, Code 39 Full ASCII