Intermec SR60 manual Label Length Format, Variable Length Format

Models: SR60

1 174
Download 174 pages 54.63 Kb
Page 131
Image 131
To set Standard 2 of 5/IATA symbology to read Variable Length Format

Chapter 4 — Enabling and Configuring Symbologies

END ------------------------------------------

Label Length Format

The next two sections let you set the Standard 2 of 5/IATA label length format to either Variable Length or Fixed Length format.

Variable Length Format

You can set the Standard 2 of 5/IATA symbology to read Variable

Length Format.

Note: For this symbology, the scanner decodes up to 50 characters, but the actual length read varies depending upon the interface type, bar code physical size, and print quality.

To set Standard 2 of 5/IATA symbology to read Variable Length Format

1Identify the minimum length setting you want to make. The selectable range is 02 to 50 characters.

2Scan the SET bar code.

3Scan the Enable Variable Length Format bar code.

4Scan the Set Minimum Label Length bar code.

5Using the Digits bar codes on page 122, scan the digits to set the minimum label length you identified in Step 1.

Note: To set a label length less than ten, you must scan a zero digit first and then the length digit (such as 04, 06, or 08).

6Scan the END bar code.

Variable Length Format

SET ------------------------------------------

SR60 Scanner Programmer’s Reference Manual

119

Page 131
Image 131
Intermec SR60 manual Label Length Format, Variable Length Format