Chapter 4 — Enabling and Configuring Symbologies
END ------------------------------------------
MSI/Plessey Options
This section describes the MSI/Plessey options and contains the programming bar codes you can use to configure those options.
About MSI/Plessey Options
The MSI/Plessey symbology has the following programmable features:
•Check Digit
•Label Length Format
•Read Verification
Check Digit
Check Digit calculates the check digit(s) to verify the labels contents have been read correctly. If you enable this feature, your bar codes must include one or two check digits. You may also choose to transmit or not transmit the check digit(s).
•The Calculate bar code on page 127 enables calculation of the check digits. The Don’t Calculate bar code disables calculation.
•The Transmit bar code on page 127 enables transmission of MSI/Plessey check digit(s). The Don’t Transmit bar code disables transmission.
•The One Check Digit bar code and the Two Check Digits bar code on page 127 specifies either one or two check digits.
Label Length Format
Label length format permits the selection between variable length or fixed length formats. For best performance, Intermec recommends that you use the Fixed Length settings when your application requires only one or two label lengths.
•The Enable Variable Length Format bar code on page 128 directs the scanner to read all labels from the minimum label
SR60 Scanner Programmer’s Reference Manual | 125 |