Cleaning the Writing Unit Glass and the Electrode Wires

Keep the writing unit glass and the electrode (corona, transfer and separator) wires clean; otherwise soil marks may be copied, resulting in dark lines on the copies. Follow the procedure below to periodically clean them.

1. Open the machine front door.

2. Withdraw and push in the writing unit glass cleaning knob and the corona wire cleaning knob, several times.

3. Firmly push in these knobs, then close the machine front door.

4. Open the right side door of the main body.

5. Release the two hooks on the top edge of the conveyance unit cover 6, then open its front cover.

DETAILS

If the hooks cannot be released easily, open the conveyance unit cover 6 to perform the following steps.

In this case, use care not to touch the drum inside the conveyance unit cover 6, and quickly perform the cleaning procedure to close the cover as soon as possible; otherwise the drum may be damaged by a long period of exposure.

WARNING

The area near the conveyance unit cover 6 generates high voltage. If touched, electrical shock may occur. DO NOT TOUCH!