terminal 2 (config-terminal:2) level commands

 

5: Commands and Levels

 

 

terminal <line>

Enters the configure-terminal level.

 

<line> = number of the terminal line (serial port) to be configured.

terminal network

Enters the configure-terminal level for the network.

terminal type <text>

Sets the terminal type.

tunnel <line>

Enters the tunnel level.

 

<line> = number of the tunnel line (serial port) to be configured.

write

Stores the current configuration in permanent memory.

terminal 2 (config-terminal:2) level commands

 

break duration <milliseconds>

Sets how long a break should last when it is being sent to the line.

 

<milliseconds> = number of milliseconds.

clrscrn

Clears the screen.

default break duration

Restores the break duration to the default value (500 ms).

default terminal type

Sets the default terminal type, "UNKNOWN".

echo disable

Disables echoing of characters received on the line back to the

 

line.

echo enable

Enables echoing of characters received on the line back to the

 

line.

exit

Exits to the configuration level.

exit connect menu disable

On the login connect menu, removes the menu item allowing the

 

user to exit

 

to the CLI.

exit connect menu enable

On the login connect menu, inserts the menu item allowing the

 

user to exit

 

to the CLI.

line <line>

Enters the line level.

 

<line> = number of the line (serial port) to be configured.

login connect menu disable

Disables the login connect menu, so a user will get the CLI imme-

 

diately

 

after logging in.

login connect menu enable

Enables the login connect menu, so a user will get the menu ra-

 

ther than the

 

CLI immediately after logging in.

no send break

Removes the configured send break character.

preview connect menu

Shows the layout of the connect menu with current settings.

send break <control>

Sets the optional send break character.

 

<text> = the character.

 

The character may be input as text, control, decimal, or hex.

 

A control character has the form <control>C.

 

A decimal value character has the form \99.

 

A hex value character has the form 0xFF.

show

Displays the current configuration.

show history

Displays the last 20 commands entered during the current CLI

 

session.

terminal <line>

Enters the configure-terminal level.

 

<line> = number of the terminal line (serial port) to be configured.

terminal network

Enters the configure-terminal level for the network.

terminal type <text>

Sets the terminal type.

tunnel <line>

Enters the tunnel level.

 

<line> = number of the tunnel line (serial port) to be configured.

write

Stores the current configuration in permanent memory.

PremierWave EN Command Reference