5: Commands and Levels

 

 

 

<number> = the number of the email profile to use.

email disconnect <number>

Sets an email profile to use to send an email alert upon closing

 

a connect mode tunnel.

 

<number> = the number of the email profile to use.

exit

Returns to the tunnel level.

flush serial disable

Characters already in the serial data buffer are retained upon es-

 

tablishing

 

a connect mode tunneling connection.

flush serial enable

Flushes the serial data buffer upon establishing a connect mode

 

tunneling

 

connection.

flush start character disable

Enables forwarding of the connect start character into the net-

 

work.

flush start character enable

Disables forwarding of the connect start character into the net-

 

work.

host <instance>

Enters the next lower level.

 

Specify the instance for the next lower level.

host mode sequential

Connects to the first host in the list that accepts the connection.

host mode simultaneous

Selects simultaneous connections to all hosts on the host list.

kill connection

Disconnects the active connect mode tunneling connection or

 

connections.

local port <number>

Sets a specific port for use as the local port.

 

<number> = the number of the port to use.

no email connect

Discontinues sending email alerts upon establishing a connect

 

mode tunnel.

no email disconnect

Discontinues sending email alerts upon closing a connect mode

 

tunnel.

promote host <number>

Promotes the identified host, exchanging it place with the host

 

above it,

 

to adjust the order of the defined hosts.

reconnect time <milliseconds>

Sets the reconnect time value for tunneling connections estab-

 

lished by the

 

device in milliseconds.

 

<milliseconds> = timeout in milliseconds.

show

Displays the current configuration.

show history

Displays the last 20 commands entered during the current CLI

 

session.

show status

Displays tunnel connect status.

start character <control>

Sets the connect mode start character.

 

The character may be input as text, control, decimal, or hex.

 

A control character has the form <control>C.

 

A decimal value character has the form \99.

 

A hex value character has the form 0xFF.

write

Stores the current configuration in permanent memory.

connect (tunnel-connect:1) level commands

 

block network disable

Forwards (tunnels) network data in connect mode tunneling.

block network enable

Discards all data coming in from the connect mode tunnel before

 

forwarding

 

it to the serial interface (generally used for debugging).

block serial disable

Forwards (tunnels) serial data in connect mode tunneling.

block serial enable

Discards all data coming in from the serial interface before for-

PremierWave EN Command Reference

63

Page 63
Image 63
Lantronix 900-581 manual Connect tunnel-connect1 level commands