Image 74
disconnect (tunnel-disconnect:3) level commands

 

5: Commands and Levels

 

 

show

Show system information

show hardware information

Displays information about the hardware.

show history

Displays the last 20 commands entered during the current CLI

 

session.

show lines

Show line information

show memory

Displays current memory usage information.

show task state

Displays current task states.

show tlog

Displays the internal trouble log.

write

Stores the current configuration in permanent memory.

diagnostics (config-diagnostics) level commands

 

clrscrn

Clears the screen.

exit

Returns to the config level.

log

Enters the next lower level.

show

Displays the current configuration.

show history

Displays the last 20 commands entered during the current CLI

 

session.

write

Stores the current configuration in permanent memory.

 

 

disconnect (tunnel-disconnect:3) level commands

clrscrn

Clears the screen.

exit

Returns to the tunnel level.

flush serial disable

Does not flush serial data upon closing a tunneling connection.

flush serial enable

Flushes serial data buffer when a tunneling connection is closed.

flush stop character disable

Forwards the stop character from the Line to the network.

flush stop character enable

Prevents the stop character from the Line from being forwarded to

 

the network.

modem control disable

Does not watch the modem control pin to disconnect.

modem control enable

Watches the modem control pin and disconnects if it is not as-

 

serted.

no stop character

Removes the stop character.

no timeout

Disables disconnect after timeout feature for tunneling sessions.

show

Displays the current configuration.

show history

Displays the last 20 commands entered during the current CLI

 

session.

stop character <control>

Sets the stop character.

 

The character may be input as text, control, decimal, or hex.

 

A control character has the form <control>C.

 

A decimal value character has the form \99.

 

A hex value character has the form 0xFF.

timeout <milliseconds>

Disconnects when no data has been received on the line (serial

 

port) for the

 

specified length of time.

 

<milliseconds> = timeout in milliseconds.

write

Stores the current configuration in permanent memory.

 

 

disconnect (tunnel-disconnect:2) level commands

 

 

clrscrn

Clears the screen.

exit

Returns to the tunnel level.

flush serial disable

Does not flush serial data upon closing a tunneling connection.

PremierWave EN Command Reference

74

Page 74
Image 74
Lantronix 900-581 Commands and Levels, PremierWave EN Command Reference, disconnect tunnel-disconnect3 level commands