Lantronix 900-581 manual Commands and Levels, PremierWave EN Command Reference

Models: 900-581

1 212
Download 212 pages 55.11 Kb
Page 62
Image 62
connect (tunnel-connect:2) level commands

 

5: Commands and Levels

 

 

 

above it,

 

to adjust the order of the defined hosts.

reconnect time <milliseconds>

Sets the reconnect time value for tunneling connections estab-

 

lished by the

 

device in milliseconds.

 

<milliseconds> = timeout in milliseconds.

show

Displays the current configuration.

show history

Displays the last 20 commands entered during the current CLI

 

session.

show status

Displays tunnel connect status.

start character <control>

Sets the connect mode start character.

 

The character may be input as text, control, decimal, or hex.

 

A control character has the form <control>C.

 

A decimal value character has the form \99.

 

A hex value character has the form 0xFF.

write

Stores the current configuration in permanent memory.

 

 

connect (tunnel-connect:2) level commands

 

block network disable

Forwards (tunnels) network data in connect mode tunneling.

block network enable

Discards all data coming in from the connect mode tunnel before

 

forwarding

 

it to the serial interface (generally used for debugging).

block serial disable

Forwards (tunnels) serial data in connect mode tunneling.

block serial enable

Discards all data coming in from the serial interface before for-

 

warding

 

it to the connect mode tunnel (generally used for debugging).

clrscrn

Clears the screen.

connect mode always

Enables the tunneling server to always establish tunneling con-

 

nections.

connect mode any character

Enables the tunneling server to establish a tunneling connection

 

when a

 

character is received on the corresponding line (serial port).

connect mode disable

Disables connect mode tunneling.

connect mode modem control asserted

Enables the tunneling server to make tunneling connections when

 

the modem

 

control pin is asserted.

connect mode modem emulation

Enables modem emulation for connect mode tunneling.

connect mode start character

Enables connect mode tunneling when the configured start char-

 

acter

 

is received on the line.

cp output

Enters the next lower level.

default connect mode

Restores the default connect mode as "disable".

default host mode

Connects to the first host in the list that accepts the connection.

default local port

Uses a random port number as the local port for establishing tun-

 

neling

 

connections to other devices.

default reconnect time

Restores the default reconnect time value for connect mode tun-

 

neling.

default start character

Defaults the connect mode start character.

email connect <number>

Sets an email profile to use to send an email alert upon establish-

 

ing

 

a connect mode tunnel.

PremierWave EN Command Reference

62

Page 62
Image 62
Lantronix 900-581 manual Commands and Levels, PremierWave EN Command Reference, connect tunnel-connect2 level commands