4 | Messaging Integration |
Messaging Integration
INTUITY AUDIX
DEFINITY ProLogix Solutions supports the following integration methods for use with the Lucent INTUITY systems:
•LAN Link
•Mode Code (in band) communications
LAN Link | The LAN link allows the DEFINITY ProLogix Solutions system and the Lucent |
| INTUITY system to communicate over a private, dedicated LAN or using a |
| customer’s LAN. The DEFINITY ProLogix Solutions system is a server, and the |
| Lucent INTUITY system is a client that always initiates the communications session. |
| This link uses a LAN circuit card installed in the Lucent INTUITY system and a C- |
| LAN circuit pack (TN799) installed in the DEFINITY ProLogix Solutions system. |
| The two systems use TCP/IP and a specialized DEFINITY protocol to communicate. |
| The LAN link provides the same functionality as a DCIU link. |
| Note: The DEFINITY ProLogix Solutions system must have Release 7 or later |
| software and must be equipped with a |
| Lucent INTUITY system must be Release 4.4 or later and must be |
| equipped with a LAN interface card. |
DEFINITY ProLogix Solutions Release 2 Overview | Issue 2 June 1999 |