Reported Event

Corrective Action

 

 

Blowers

 

 

 

Blowers have started

Normal.

 

 

Blowers have stopped

Verify that the cooling unit is properly installed. If the

 

blower still does not turn, replace the blowers.

 

 

Blower speed is

Check the Astra ES for overheating.

increased

 

 

 

Blower speed is

Temporary overheat condition was corrected.

decreased

 

 

 

Blowers are NOT

Replace the blowers.

functioning

 

 

 

Blowers have been

Normal.

inserted

 

 

 

Blowers have been

Reinstall the cooling unit(s). If the blowers do not

removed

turn, replace the blowers.

 

 

Blowers are functioning

Normal.

normally

 

 

 

Blowers are NOT

Reinstall the cooling unit(s). If the blowers do not

installed

turn, replace the blowers.

 

 

Blower status is unknown

Check for airflow out of the cooling unit. If there is

 

none, check for proper installation.

 

 

 

(Blowers Events)

Reported Event

Corrective Action

Cache

BBU flushing has started

Astra ES cache is being flushed.

 

 

BBU flushing has ended

Astra ES cache has been flushed.

 

 

BBU flushing has failed

Astra ES cache could not be flushed. Check your

 

cache flush interval setting.

 

 

 

(Cache Events)