Reported Event | Corrective Action |
|
|
Controller |
|
|
|
The controller | The user successfully change controller settings. |
parameter(s) changed by |
|
user |
|
|
|
The controller has new | Check the event logs. |
crash information |
|
|
|
Controller temperature is | The Astra ES controller is overheating. Check for |
above the | airflow around and through the controller, and verify |
threshold/warning | that all fans are working. Replace fans as needed. |
threshold |
|
|
|
Controller temperature is | The Astra ES controller is seriously overheating. |
above the critical | Check for airflow around and through the controller, |
threshold | and verify that all fans are working. Replace fans as |
| needed. |
|
|
| (Controller Events) |
Reported Event | Corrective Action |
|
|
Disk Array |
|
|
|
New disk array has been | Result of settings or user action. Normal. |
created |
|
|
|
Disk array has been | Result of settings or user action. Normal. |
deleted |
|
|
|
Disk array has been | Result of settings or user action. Normal. |
added |
|
|
|
Disk array has been | The physical drives of the disk array were removed |
removed | from the enclosure. |
|
|
Disk array settings have | The user successfully logical drive settings. |
been changed |
|
|
|
(Disk Array Events)