Reported Event | Corrective Action |
|
|
Logical Drive |
|
|
|
Logical drive initialization | Result of user action. Normal. |
has started |
|
|
|
Logical drive initialization | Logical drive is ready to use. Normal. |
has completed |
|
|
|
Logical drive initialization | Initialization paused because of user intervention, |
has paused | schedule or a higher priority background activity. |
|
|
Logical drive initialization | Initialization has resumed again after a pause. |
has resumed |
|
|
|
Logical drive initialization | Initialization stopped because of user intervention, |
has stopped | schedule or the logical drive was deleted or went |
| critical or offline. |
|
|
Logical drive initialization | Initialization failure due to a failed disk drive. Replace |
marks the logical drive | the disk drive, delete and recreate the logical drive. |
offline |
|
|
|
Logical drive initialization | System resources are low. Reduce system load or |
is aborted due to an | restart the Astra ES. |
internal error. |
|
|
|
Logical drive initialization | Initialization has been set manually or by schedule. |
is queued |
|
|
|
A new logical drive has | Result of user action. Normal. |
been created |
|
|
|
Logical drive has been | Result of user action. Normal. |
deleted |
|
|
|
Logical drive has been | The physical drives of the array are restored to |
placed online | online status. |
|
|
Logical drive has been | One or more physical drives in the array went offline. |
placed online. Possible |
|
data loss |
|
|
|
Logical drive has been | One or more physical drives in the array went offline. |
set to critical. |
|
|
|
Logical drive axle has | RAID 50. One of the axles (RAID 5 arrays) returned |
been placed online | on online status. |
|
|