You can set or adjust the following items:

Alias, if assigned

Coercion, enable or disable

Coercion Method

SMART – Self-Monitoring, Analysis, and Reporting System for physical drives.

SMART Polling Interval

Write Back Cache Flush Interval

Enclosure Polling Interval

LUN Affinity

Upgradable items

You can upgrade the following items:

Boot loader Version

Firmware Version number

Software Version number

Memory Size

Viewing Controller Statistics

To view controller statistics:

1.Click the Subsystem icon in Tree View.

2.Click the Controllers icon.

3.Click the Controller icon.

4.Click the Information tab in Management View and select Statistics from dropdown menu.

Clearing Statistics

Modifying Controller Settings

To modify Controller settings:

1.Click the Subsystem icon in Tree View.

2.Click the Controllers icon.

3.Click the Controller icon.

4.Click the Settings tab in Management View.

5.Make the following settings as needed:

Enter a name into the Alias field.

Maximum of 48 characters. Use letters, numbers, space between words, and underscore. An alias is optional.

Fibre Channel models only. Check the Enable LUN affinity box to enable the LUN affinity feature.

Check the SMART Log box to enable the Self-Monitoring, Analysis, and Reporting System (SMART).

Enter a polling interval (1 to 1440 minutes) in SMART Polling Interval field.

Check the Coercion Enabled box to enable disk drive capacity coercion.

When disk drives of different capacities are used in the same array, coercion reduces the usable capacity of the larger disk drive(s) in order to match the smallest capacity drive.

Select a coercion method from the Coercion Method dropdown menu. The choices are:

GB Truncate – (Default) Reduces the useful capacity to the nearest 1,000,000,000 byte boundary. 10GB Truncate – Reduces the useful capacity to the nearest 10,000,000,000 byte boundary.

Group Rounding – Uses an algorithm to determine how much to truncate. Results in the maximum amount of usable drive capacity.

Table Rounding – Applies a predefined table to determine how much to truncate.

Enter a time interval (1 to 12 seconds) in the Write Back Cache Flush Interval field.

Enter a time interval (15 to 255 seconds) in the Enclosure Polling Interval field.

Check the Adaptive Writeback Cache box to enable the Adaptive Writeback Cache feature.

50

EXCEL MERIDIAN DATA

Page 50
Image 50
Meridian Data 1 manual Viewing Controller Statistics, Modifying Controller Settings, Upgradable items