11 TROUBLESHOOTING
Special Relay List
(3) System clocks/counters
Number | Name |
|
|
|
|
|
|
|
| Meaning |
| Explanation | Set by | Corresponding | Applicable | ||||||||||
|
|
|
|
|
|
|
|
| (When Set) | ACPU | CPU | ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| M9 | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
SM400 | Always ON |
|
| ON |
|
|
|
|
|
|
|
|
|
| • Normally is ON | S | M9036 |
| |||||||
|
|
|
|
|
|
|
|
|
|
|
| (Every END |
| ||||||||||||
|
| OFF |
|
|
|
|
|
| |||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| processing) |
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
SM401 | Always OFF | ON |
|
|
|
|
|
|
|
|
|
|
|
| S |
|
| ||||||||
|
|
|
|
| • Normally is OFF | (Every END | M9037 |
| |||||||||||||||||
OFF |
|
|
|
|
|
|
| ||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| processing) |
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| ON for 1 scan | ON | 1 scan | • After RUN, ON for 1 scan only. | S |
|
| ||||||||||||||||||
SM402 | • This connection can be used for scan execution type | (Every END | M9038 |
| |||||||||||||||||||||
only after RUN | OFF |
|
|
|
|
|
|
|
|
| |||||||||||||||
|
|
|
|
|
|
|
|
| |||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| programs only. | processing) |
|
| |||||||
| After RUN, OFF | ON |
|
|
|
|
|
|
|
| • After RUN, OFF for 1 scan only. | S |
|
| |||||||||||
SM403 |
|
| 1 scan | • This connection can be used for scan execution type | (Every END | M9039 |
| ||||||||||||||||||
| for 1 scan only | OFF |
|
|
|
|
| programs only. | processing) |
|
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
| Low speed |
|
|
|
|
|
|
|
|
|
|
|
|
| • After RUN, ON for 1 scan only. | S |
|
| |||||||
| execution type |
| ON | 1 scan |
|
| |||||||||||||||||||
SM404 | program |
| • This connection can be used for low speed execution | (Every END | New |
| |||||||||||||||||||
| OFF |
|
|
|
|
|
| ||||||||||||||||||
| ON for 1 scan |
|
|
|
|
|
|
|
| type programs only. | processing) |
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
| only after RUN |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Low speed |
|
|
|
|
|
|
|
|
|
|
|
|
| • After RUN, OFF for 1 scan only. | S |
|
| |||||||
| execution type | ON |
|
|
|
|
|
|
|
|
| ||||||||||||||
SM405 | program |
| 1 scan | • This connection can be used for low speed execution | (Every END | New |
| ||||||||||||||||||
OFF |
| ||||||||||||||||||||||||
| After RUN, OFF |
|
|
|
|
| type programs only. | processing) |
|
| |||||||||||||||
| for 1 scan only |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| • Repeatedly changes between ON and OFF at |
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| interval. |
|
|
| |||||||
SM409 | 0.01 second |
|
| 0.005 sec. |
|
|
|
|
| • When PLC power supply is turned OFF or a CPU module | S (Status | New | QCPU | ||||||||||||
|
| 0.005 sec. | reset is performed, goes from OFF to start. | ||||||||||||||||||||||
| clock |
|
|
|
|
|
|
|
|
|
|
|
|
| • Note that the | change) |
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| designated time has elapsed during the execution of the |
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| program. |
|
|
| |||||||
SM410 | 0.1 second clock |
| 0.05 sec. | 0.05 sec. | • Repeatedly changes between ON and OFF at each |
| M9030 |
| |||||||||||||||||
|
|
|
|
|
|
|
|
|
| ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| designated time interval. |
|
|
| |||||||
|
|
|
| 0.1sec. |
|
|
|
|
|
|
|
| |||||||||||||
SM411 | 0.2 second clock |
|
| 0.1sec. | • When PLC power supply is turned OFF or a CPU module |
| M9031 |
| |||||||||||||||||
|
|
|
|
|
|
|
| S (Status |
| ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| reset is performed, goes from OFF to start. |
|
| ||||||||
|
|
| 0.5 sec. |
|
|
|
|
| change) |
|
| ||||||||||||||
SM412 | 1 second clock |
| 0.5 sec. | • Note that the | M9032 |
| |||||||||||||||||||
|
|
|
|
|
|
|
|
|
| ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| designated time has elapsed during the execution of the |
|
|
| |||||||
|
|
| 1 sec. |
|
|
|
|
|
|
|
| ||||||||||||||
SM413 | 2 second clock |
| 1 sec. | program. |
| M9033 |
| ||||||||||||||||||
|
|
|
|
|
|
|
|
|
| ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| • Goes between ON and OFF in accordance with the |
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| number of seconds designated by SD414. |
|
|
| |||||||
SM414 | 2n second clock |
| n sec. |
|
|
|
|
| • When PLC power supply is turned OFF or a CPU module | S (Status | M9034 format |
| |||||||||||||
| n sec. | reset is performed, goes from OFF to start. |
| ||||||||||||||||||||||
|
|
|
|
|
|
|
| change) | change |
| |||||||||||||||
|
|
|
|
|
|
|
|
|
| • Note that the |
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| designated time has elapsed during the execution of the |
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| program. |
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| • Switches between ON and OFF in accordance with the |
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| number of milliseconds designated by SD415. |
|
|
| |||||||
SM415 | 2n (ms) clock | n(ms) |
|
|
|
|
| • When PLC power supply is turned OFF or a CPU module | S (Status | New | QCPU | ||||||||||||||
n(ms) | reset is performed, goes from OFF to start. | ||||||||||||||||||||||||
|
|
|
|
|
|
|
| change) | |||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| • Note that the |
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| designated time has elapsed during the execution of the |
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| program. |
|
|
| |||||||
SM420 | User timing clock |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| M9020 |
| |
| No.0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
SM421 | User timing clock |
|
|
|
|
|
|
|
|
|
|
|
|
| • Relay repeats ON/OFF switching at fixed scan intervals. |
| M9021 |
| |||||||
| No.1 |
|
|
|
|
|
|
|
|
|
|
|
|
| • When PLC power supply is turned OFF or a CPU module | S |
|
| |||||||
| User timing clock |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
SM422 |
|
|
|
|
|
|
|
|
|
|
|
|
| reset is performed, goes from OFF to start. | (Every END | M9022 |
| ||||||||
No.2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| • The ON/OFF intervals are set with the DUTY instruction. |
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| processing) |
|
| ||||||||
| User timing clock |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
SM423 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| DUTY | n1 | n2 | SM420 |
|
|
| M9023 |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
| No.3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
SM424 | User timing clock |
|
| n2 | n2 |
|
|
|
|
|
|
|
| M9024 |
| ||||||||||
No.4 |
|
| scan | scan |
|
|
|
|
|
|
|
|
|
| |||||||||||
SM430 | User timing clock |
|
|
|
|
|
|
|
| n1 |
|
|
|
|
|
|
|
|
|
| |||||
No.5 |
|
|
|
|
|
|
|
| scan |
|
|
|
|
|
|
|
|
|
| ||||||
SM431 | User timing clock |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| No.6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| S |
|
| |
| User timing clock |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
SM432 |
|
|
|
|
|
|
|
|
|
|
|
|
| • For use with SM420 to SM424 low speed programs. | (Every END | New |
| ||||||||
| No.7 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| processing) |
|
| |
SM433 | User timing clock |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
No.8 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
SM434 | User timing clock |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
No.9 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
11 - 47 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 11 - 47 |