11 TROUBLESHOOTING

MELSEC-Q

Special Register List (Continued)

 

 

 

 

Set by

Corresponding

Corresponding

Number

Name

Meaning

Explanation

ACPU

(When set)

CPU

 

 

 

 

D9

 

 

 

 

 

 

The following bit patterns are used to store the statuses of the LEDs on the CPU module:

0 indicates OFF, 1 ON, and 2 flicker.

 

 

 

B15

B12B11

B8 B7

B4 B3

B0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

7

6

5

 

4

3

2

1

 

S (Status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

New

QCPU

 

 

1

: RUN

 

 

5

: BOOT

 

 

 

 

 

 

 

 

 

 

change)

 

 

2

: ERROR

 

 

6

: Vacant

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 : USER

 

 

7

: Vacant

 

 

 

 

 

 

 

 

4

: BAT.ALARM

 

8

: MODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bit patterns for MODE

 

 

 

SD201 LED status

Status of

 

 

 

 

 

 

 

0: OFF, 1: Green,

 

 

 

 

 

CPU-LED

 

 

 

 

 

 

 

2: Orange

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Information concerning which of the following status the LEDs on the CPU module are in is stored in the following bit patterns:

0 is off, 1 is on, and 2 is flicker

 

 

 

 

 

B15

B12B11

B8 B7

B4 B3

B0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S (Status

New

QnA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

7

6

5

4

3

2

1

 

 

 

 

 

change)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 : RUN

 

 

 

5 : BOOT

 

 

 

 

 

 

 

 

 

 

 

2 : ERROR

 

 

 

6 : CARD A (Memory card)

 

 

 

 

 

 

 

3 : USER

 

 

 

7 : CARD B (Memory card)

 

 

 

 

 

 

 

4 : BAT.ALARM

 

 

8 : Vacant

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bit pattern of

• Stores bit patterns of LEDs turned off

 

 

 

 

 

 

 

 

SD202

LED off

LED that is

(Only USER and BOOT enabled)

 

 

 

 

 

 

U

New

QnA

 

 

turned off

• Turned off at 1, not turned off at 0

 

 

 

 

 

 

 

 

 

 

 

 

• The operating status of the remote I/O module is stored in the

 

 

 

 

 

 

following format.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B15

 

 

 

 

B4 B3

B0

S (Always)

New

Remote

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vacant

 

 

 

 

1

 

 

 

 

 

 

 

 

1 Remote I/O module operating status

 

Always 2: STOP

 

 

 

 

 

 

• The CPU module operating status is stored as indicated in the

 

 

 

 

 

 

following figure:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B15

B12B11

B8 B7

B4 B3

B0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operating

Operating

 

 

 

 

 

 

2

 

 

 

1

 

 

 

 

SD203

status of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

status of CPU

 

1 : Operating status of CPU

 

0 :RUN

 

 

 

 

 

 

 

 

 

CPU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 :STEP-RUN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S (Every

 

 

 

 

 

 

 

 

 

 

 

2 :STOP

 

 

 

 

 

D9015 format

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

END

 

 

 

 

 

 

 

 

 

 

3 :PAUSE

 

 

 

 

 

change

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

processing)

 

 

 

 

 

2 : STOP/PAUSE cause

 

0 :Switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 :Remote contact

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 : Remote operation from the

 

 

 

 

 

 

 

 

 

 

 

 

GX Developer or Serial

 

 

 

 

 

 

 

 

 

 

 

 

Communication.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 :Internal program instruction

 

 

 

 

 

 

 

Note: Priority is earliest first

 

4 :Errors

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0: Test not yet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

executed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Device test

1: During X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

device test

 

 

 

 

 

 

 

 

 

 

 

 

S

 

 

SD206

execution

• Set when the device test mode is executed on GX Developer.

New

Remote

 

type

2: During Y

 

 

 

 

 

 

 

 

 

 

 

 

(Request)

 

 

 

device test

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3:During X/Y device test

11 - 72

11 - 72