11 TROUBLESHOOTING
Special Relay List (Continued)
ACPU | Special | Special |
|
|
| Applicable | |||
Special | Relay after | Relay for | Name | Meaning | Details | ||||
CPU | |||||||||
Relay | Conversion | Modification |
|
|
| ||||
|
|
|
| ||||||
|
|
|
|
| ZNRD instruction |
| • Depends on whether or not the ZNRD (word device read) |
| |
M9200 | SM1200 |
|
|
| (LRDP instruction | OFF: Not accepted | instruction has been received. |
| |
|
|
| for ACPU) | ON : Accepted | • Used in the program as an interlock for the ZNRD |
| |||
|
|
|
| ||||||
|
|
|
|
| reception (for | instruction. |
| ||
|
|
|
|
|
|
| |||
|
|
|
|
| master station) |
| • Use the RST instruction to reset. |
| |
|
|
|
|
| ZNRD instruction |
| • Depends on whether or not the ZNRD (word device read) |
| |
M9201 | SM1201 |
|
|
| (LRDP instruction | OFF: Not completed | instruction execution is complete. |
| |
|
|
| for ACPU) | ON : End | • Used as a condition contact for resetting SM1202 and |
| |||
|
|
|
| ||||||
|
|
|
|
| completion (for | SM1203 after the ZNRD instruction is complete. |
| ||
|
|
|
|
|
|
| |||
|
|
|
|
| master station) |
| • Use the RST instruction to reset. |
| |
|
|
|
|
| ZNWR instruction |
| • Depends on whether or not the ZNWR (word device |
| |
M9202 | SM1202 |
|
|
| (LWTP instruction | OFF: Not accepted | write) instruction has been received. |
| |
|
|
| for ACPU) | ON : Accepted | • Used in the program as an interlock for the ZNWR |
| |||
|
|
|
| ||||||
|
|
|
|
| reception (for | instruction. |
| ||
|
|
|
|
|
|
| |||
|
|
|
|
| master station) |
| • Use the RST instruction to reset. |
| |
|
|
|
|
| ZNWR instruction |
| • Depends on whether or not the ZNWR (word device |
| |
|
|
|
|
| (LWTP instruction | OFF: Not completed | write) instruction execution is complete. |
| |
M9203 | SM1203 |
|
|
| for ACPU) | ON : End | • Used as a condition contact to reset SM1202 and |
| |
|
|
|
| ||||||
|
|
|
|
| completion (for | SM1203 after the ZNWR instruction is complete. |
| ||
|
|
|
|
|
|
| |||
|
|
|
|
| master station) |
| • Use the RST instruction to reset. |
| |
|
|
|
|
| ZNRD instruction |
|
|
| |
M9204 | SM1204 |
|
|
| (LRDP instruction | OFF: Not completed | On indicates that the ZNRD instruction is complete at the |
| |
|
|
| for ACPU) | ON : End | local station. |
| |||
|
|
|
| ||||||
|
|
|
|
| reception (for local |
| |||
|
|
|
|
| station) |
|
|
| |
|
|
|
|
| ZNWR instruction |
|
|
| |
M9205 | SM1205 |
|
|
| (LWTP instruction | OFF: Not completed | On indicates that the ZNWR instruction is complete at the |
| |
|
|
| for ACPU) | ON : End | local station. |
| |||
|
|
|
| ||||||
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
| ||
|
|
|
|
| local station) |
|
|
| |
M9206 | SM1206 |
|
|
| Host station link | OFF: Normal | Depends on whether or not the link parameter setting of |
| |
|
|
| parameter error | ON : Abnormal | the host is valid. |
| |||
|
|
|
|
|
| ||||
|
|
|
|
|
|
| Depends on whether or not the link parameter setting of | QnA | |
M9207 | SM1207 |
|
|
| Link parameter | OFF: YES | the master station in tier two matches that of the master | ||
|
|
|
| ||||||
|
|
| check results | ON : NO | station in tier three in a |
| |||
|
|
|
|
|
| ||||
|
|
|
|
|
|
| (Valid only for the master stations in a |
| |
|
|
|
|
| Sets master |
| • Depends on whether or not the B and W data controlled |
| |
|
|
|
|
|
| by |
| ||
|
|
|
|
| station B and W |
|
| ||
|
|
|
|
| OFF: Transmits to tier2 and |
| |||
|
|
|
|
| transmission |
| |||
M9208 | SM1208 |
|
|
| tier 3 | • When SM1208 is OFF .......B and W of host station is |
| ||
|
|
| range (for lower |
| |||||
|
|
|
|
| ON : Transmits to tier2 only | sent to tertiary stations. |
| ||
|
|
|
|
| link master |
| |||
|
|
|
|
|
| • When SM1208 is ON .........B and W of host station is |
| ||
|
|
|
|
| stations only) |
|
| ||
|
|
|
|
|
| not sent to tertiary stations. |
| ||
|
|
|
|
| Link parameter |
| • Set to ON not to match B and W of the higher and lower |
| |
M9209 | SM1209 |
|
|
| check command | OFF: Executing the check | links. (When SM1209 is ON, the link parameters of the |
| |
|
|
| (for lower link | function | higher and lower links are not checked.) |
| |||
|
|
|
| ||||||
|
|
|
|
| master stations | ON : Check | • When SM1209 is OFF, the link parameters of the higher |
| |
|
|
|
|
| only) |
| and lower links are checked. |
| |
M9210 | SM1210 |
|
|
| Link card error (for | OFF: Normal | Depends on presence or absence of the link card |
| |
|
|
| master station) | ON : Abnormal | hardware error. Judged by the CPU. |
| |||
|
|
|
|
|
| ||||
M9211 | SM1211 |
|
|
| Link module error | OFF: Normal | Depends on presence or absence of the link card |
| |
|
|
| (for local station | ON : Abnormal | hardware error. Judged by the CPU. |
| |||
|
|
|
| ||||||
|
|
|
|
| use) |
| |||
|
|
|
|
|
|
|
| ||
|
|
|
|
|
| OFF: Online |
|
| |
M9224 | SM1224 |
|
|
| Link status | ON : | Depends on whether the master station is online or offline |
| |
|
|
| test, or | or is in |
| ||||
|
|
|
|
|
|
| |||
|
|
|
|
|
| test |
|
| |
M9225 | SM1225 |
|
|
| Forward loop error | OFF: Normal | Depends on the error condition of the forward loop line. |
| |
|
|
| ON : Abnormal |
| |||||
|
|
|
|
|
|
|
| ||
M9226 | SM1226 |
|
|
| Reverse loop error | OFF: Normal | Depends on the error condition of the reverse loop line. |
| |
|
|
| ON : Abnormal |
| |||||
|
|
|
|
|
|
|
| ||
M9227 | SM1227 |
|
|
|
| OFF: Not being executed | Depends on whether or not the master station is executing |
| |
|
|
| Loop test status | ON : Forward or reverse loop |
| ||||
|
|
| a forward or a reverse loop test. |
| |||||
|
|
|
|
|
| test execution underway |
| ||
M9232 | SM1232 |
|
|
| Local station | OFF: RUN or STEP RUN | Depends on whether or not a local station is in STOP or |
| |
|
|
| status |
| |||||
|
|
| operation status | PAUSE mode. |
| ||||
|
|
|
|
| ON : STOP or PAUSE status |
| |||
|
|
|
|
|
|
|
|
11 - 57 | 11 - 57 |