11 TROUBLESHOOTING

MELSEC-Q

Special Relay List (Continued)

ACPU

Special

Special

 

 

 

 

Applicable

Special

Relay after

Relay for

Name

 

Meaning

Details

 

CPU

Relay

Conversion

Modification

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF: Other than when P, I set

• Provides P, I set request after transfer of the other

 

M9061

SM1061

 

Sub program 3 P,

program (for example subprogram when main program is

 

 

I set request

 

being requested

being run) is complete during run. Automatically switched

 

 

 

 

ON

: P, I set being requested

 

 

 

 

 

off when P, I setting is complete.

 

 

 

 

 

 

 

 

 

 

 

Divided

OFF: Divided processing not

• Turned on when canvas screen transfer to

 

 

 

 

processing

 

M9065

SM1065

SM711

 

underway

AD57(S1)/AD58 is done by divided processing, and

 

execution

 

 

 

 

 

ON

: During divided processing

turned off at completion of divided processing.

QnA

 

 

 

detection

 

 

 

 

 

 

 

 

 

Divided

OFF: Batch processing

• Turned on when canvas screen transfer to

 

M9066

SM1066

SM712

processing

 

ON

: Divided processing

AD57(S1)/AD58 is done by divided processing.

 

 

 

 

request flag

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Turned ON to shorten the search time in the

 

M9070

SM1070

 

A8UPU/A8PUJre

OFF: Read time not shortened

A8UPU/A8PUJ.

 

 

quired search

ON : Read time shortened

(In this case, the scan time is extended by 10 %.)

 

 

 

 

time

The A8UPU/A8PUJ cannot be used in the

 

 

 

 

 

 

 

 

 

 

 

 

 

QCPU/QnACPU special relays.

 

 

 

 

 

OFF: Empty spaces in

 

 

 

 

 

Communication

 

communication request

• Indication of communication enable/disable to remote

 

 

 

 

request

 

registration area

 

M9081

SM1081

SM714

 

terminal modules connected to the MELSECNET/MINI

QnA

registration area

ON

: No empty spaces in

 

 

 

master, A2C or A52G.

 

 

 

 

BUSY signal

 

communication request

 

 

 

 

 

 

 

 

 

 

 

 

registration area

 

 

 

 

 

 

 

 

• It is set whether the error checks below are performed or

 

 

 

 

 

 

 

not when the END instruction is processed (to set the

 

M9084

SM1084

 

Error check

OFF: Error check executed

END instruction processing time).

 

 

ON

: No error check

• Check for breakage of fuse.

 

 

 

 

 

 

 

 

 

 

 

 

• Collation check of I/O unit

 

 

 

 

 

 

 

• Check of battery

 

M9091

SM1091

 

Instruction error

OFF: No error

• Set when an operation error detail factor is stored at

 

 

flag

ON

: Error

SD1091, and remains set after normal status is restored.

 

 

 

 

 

 

 

 

 

 

 

• After the head address of the required I/O module is set

 

 

 

 

 

 

 

to SD251, switching SM251 on allows the I/O module to

 

 

 

 

 

 

 

be changed in online mode. (One module is only allowed

 

 

 

 

 

 

 

to be changed by one setting.)

 

M9094

SM1094

SM251

I/O change flag

OFF: Replacement

• To be switched on in the program or peripheral device

QnA

ON : No replacement

test mode to change the module during CPU RUN. To be

 

 

 

 

 

 

 

 

 

 

 

switched on in peripheral device test mode to change the

 

 

 

 

 

 

 

module during CPU STOP.

 

 

 

 

 

 

 

• RUN/STOP mode must not be changed until I/O module

 

 

 

 

 

 

 

change is complete.

 

M9100

SM1100

SM320

Presence/absenc

OFF: SFC programs not used

• Turned on if the SFC program is registered, and turned

 

e of SFC

ON

: SFC programs used

off if it is not.

 

 

 

 

program

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Should be turned on by the program if the SFC program

 

M9101

SM1101

SM321

Start/stop SFC

OFF: SFC programs stop

is to be started. If turned off, operation output of the

 

program

ON

: SFC programs start

execution step is turned off and the SFC program is

 

 

 

 

 

 

 

 

 

 

 

stopped.

 

 

 

 

 

 

 

• Selects the starting step when the SFC program is

 

 

 

 

 

 

 

restarted using SM322.

 

 

 

 

 

 

 

ON: All execution conditions when the SFC program

 

 

 

 

 

 

 

stopped are cleared, and the program is started

 

 

 

 

SFC program

OFF: Initial Start

with the initial step of block 0.

 

M9102

SM1102

SM322

OFF: Started with the step of the block being executed

 

start status

ON

: Continue

 

 

 

 

when the program stopped.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Once turned on, the program is latched in the system and

 

 

 

 

 

 

 

remains on even if the power is turned off.

 

 

 

 

 

 

 

Should be turned off by the sequence program when

 

 

 

 

 

 

 

turning on the power, or when starting with the initial step

 

 

 

 

 

 

 

of block 0.

 

 

 

 

 

OFF: Continuous transition not

• Selects consecutive or step-by-step transfer of steps of

 

 

 

 

Presence/absenc

which transfer conditions are established when all of the

 

M9103

SM1103

SM323

e of continuous

 

effective

transfer conditions of consecutive steps are established.

 

ON

: Continuous transition

 

 

 

 

transition

ON: Consecutive transfer is executed.

 

 

 

 

 

effective

 

 

 

 

 

 

OFF: One step per one scan is transferred.

 

 

 

 

 

 

 

 

11 - 55

11 - 55