11 TROUBLESHOOTING

MELSEC-Q

Special Relay List (Continued)

ACPU

Special

Special

 

 

 

 

 

 

Applicable

Special

Relay after

Relay for

Name

 

 

Meaning

Details

 

 

CPU

Relay

Conversion

Modification

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Set when consecutive transfer is not executed with

 

 

 

 

Continuous

OFF: When transition is

consecutive transfer enabled. Reset when transfer of one

 

M9104

SM1104

SM324

transition

completed

 

step is completed.

 

 

 

 

suspension flag

ON : When no transition

Consecutive transfer of a step can be prevented by

 

 

 

 

 

 

 

 

 

writing an AND condition to corresponding SM324.

 

 

 

 

Step transition

 

 

 

 

 

 

M9108

SM1108

SM90

watchdog timer

 

 

 

 

 

 

start (equivalent

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of D9108)

 

 

 

 

 

 

 

 

 

Step transition

 

 

 

 

 

 

M9109

SM1109

SM91

watchdog timer

 

 

 

 

 

 

start (equivalent

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of D9109)

 

 

 

 

 

 

 

 

 

Step transition

 

 

 

 

 

 

M9110

SM1110

SM92

watchdog timer

 

 

 

 

 

 

start (equivalent

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of D9110)

 

 

 

 

 

 

 

 

 

Step transition

OFF: Watchdog timer reset

• Turned on when the step transfer monitoring timer is

 

 

 

 

watchdog timer

 

M9111

SM1111

SM93

ON : Watchdog timer reset

 

start (equivalent

started. Turned off when the monitoring timer is reset.

 

 

 

 

start

 

 

 

 

 

 

of D9111)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Step transition

 

 

 

 

 

 

M9112

SM1112

SM94

watchdog timer

 

 

 

 

 

 

start (equivalent

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of D9112)

 

 

 

 

 

 

 

 

 

Step transition

 

 

 

 

 

 

M9113

SM1113

SM95

watchdog timer

 

 

 

 

 

 

start (equivalent

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of D9113)

 

 

 

 

 

 

 

 

 

Step transition

 

 

 

 

 

 

M9114

SM1114

SM96

watchdog timer

 

 

 

 

 

 

start (equivalent

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of D9114)

 

 

 

 

 

 

 

 

 

Active step

OFF: Trace started

• Set when sampling trace of all specified blocks is

 

M9180

SM1180

SM825

sampling trace

 

ON : Trace completed

completed. Reset when sampling trace is started.

 

 

 

 

completion flag

 

 

 

 

 

 

 

 

 

 

M9181

SM1181

SM822

Active step

OFF: Trace not being executed

• Set when sampling trace is being executed.

 

sampling trace

ON : Trace execution under

Reset when sampling trace is completed or suspended.

 

 

 

 

execution flag

way

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Selects sampling trace execution enable/disable.

 

 

 

 

Active step

OFF: Trace disable/suspend

ON: Sampling trace execution is enabled.

 

M9182

SM1182

SM821

sampling trace

OFF: Sampling trace execution is disabled.

 

ON : Trace enable

 

 

 

 

permission

If turned off during sampling trace execution, trace

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

is suspended.

 

 

 

 

 

 

 

 

 

• Selects the operation output when block stop is

 

 

 

 

 

 

 

 

 

executed.

 

 

 

 

 

 

 

 

 

ON: Retains the ON/OFF status of the coil being used

 

M9196

SM1196

SM325

Operation output

OFF: Coil output OFF

by using operation output of the step being

 

at block stop

ON : Coil output ON

executed at block stop.

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF: All coil outputs are turned off. (Operation output by

 

 

 

 

 

 

 

 

 

the SET instruction is retained regardless of the

 

 

 

 

 

 

 

 

 

ON/OFF status of M9196.)

 

 

 

 

 

 

 

 

I/O numbers

 

 

 

 

 

 

SM1197

SM1198

to be

 

 

M9197

SM1197

 

 

 

 

 

displayed

 

 

 

Switch between

OFF

 

OFF

X/Y

Switches I/O numbers in the fuse blow module storage

 

 

 

 

 

0 to 7F0

 

 

 

 

blown fuse and

 

 

 

registers (SD1100 to SD1107) and I/O module verify error

 

 

 

 

 

 

 

X/Y

 

 

 

 

I/O verification

ON

 

OFF

storage registers (SD1116 to SD1123) according to the

 

 

 

 

 

800 to FF0

 

 

 

 

error display

 

 

 

combination of ON/OFF of the SM1197 and SM1198.

 

 

 

 

OFF

 

ON

X/Y

 

 

 

 

 

 

 

 

M9198

SM1198

 

 

 

1000 to 17F0

 

 

 

 

 

 

 

 

 

 

 

ON

 

ON

X/Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1800 to 1FF0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Data recovery of

 

 

 

 

• Recovers the setting data stored in the CPU at restart

 

 

 

 

OFF: Data recovery disabled

when sampling trace/status latch is executed.

 

M9199

SM1199

 

online sampling

 

 

ON : Data recovery enabled

• SM1199 should be ON to execute again. (Unnecessary

 

 

 

 

trace/status latch

 

 

 

 

 

 

 

 

 

when writing the data again from peripheral devices.)

 

11 - 56

11 - 56