11 TROUBLESHOOTING
Special Register List (Continued)
ACPU | Special | Special |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Corresponding | |
Special | Register after | Register for | Name | Meaning |
|
|
|
|
|
|
| Details | |||||||||||
|
|
|
|
|
|
| CPU | ||||||||||||||||
Conversion | Conversion | Modification |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
| • When SM803 is turned ON/OFF by peripheral device |
| |||||||||||||||||
|
|
|
|
| to activate sampling trace |
| STRA | , | STRAR | , value |
| ||||||||||||
D9044 | SD1044 |
| For sampling | Step or time during | stored in SD1044 is used as sampling trace condition. |
| |||||||||||||||||
| trace | sampling trace | For scan ....... 0 |
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
| For time ....... Time (10ms increments) |
| |||||||||||||||||
|
|
|
|
| Value is stored into SD1044 in BIN code. |
| |||||||||||||||||
|
|
|
| Extension file | • Stores the block number of the expansion file register |
| |||||||||||||||||
|
|
|
| which is used as the work area for the execution of a |
| ||||||||||||||||||
|
|
|
| register block No. |
| ||||||||||||||||||
|
|
| Work area for | SFC program in a binary value. |
| ||||||||||||||||||
D9049 | SD1049 |
| used as SFC |
| |||||||||||||||||||
| SFC | • Stores "0" if an empty area of 16K bytes or smaller, |
| ||||||||||||||||||||
|
|
| program execution |
| |||||||||||||||||||
|
|
|
| which cannot be expansion file register No. 1, is used |
| ||||||||||||||||||
|
|
|
| work area |
| ||||||||||||||||||
|
|
|
| or if SM320 is OFF. |
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
| • Stores code numbers of errors occurred in the SFC |
| |||||||||||||||||
|
|
|
|
| program in BIN code. |
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
| 0: |
| No error |
|
|
|
|
|
|
|
|
|
| ||||||
|
|
| SFC program | Error code |
| 80: SFC program parameter error |
| ||||||||||||||||
D9050 | SD1050 |
| generated by SFC |
| 81: SFC code error |
|
|
|
|
|
|
|
|
|
| ||||||||
| error number |
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
| program |
| 82: Number of steps of simultaneous execution |
| |||||||||||||||||
|
|
|
|
|
| ||||||||||||||||||
|
|
|
|
|
|
|
| exceeded |
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
| 83: |
| Block start error |
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
| 84: SFC program operation error |
| ||||||||||||||||
|
|
|
| Block number | • Stores the block number in which an error occurred in |
| |||||||||||||||||
|
|
|
| the SFC program in BIN code. |
| ||||||||||||||||||
D9051 | SD1051 |
| Error block | where error |
| ||||||||||||||||||
| In the case of error 83 the starting block number is |
| |||||||||||||||||||||
|
|
|
| occurred |
| ||||||||||||||||||
|
|
|
| stored. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
| • Stores the step number in which error 84 occurred in |
| |||||||||||||||||
|
|
|
| Step number where | the SFC program in BIN code. |
| |||||||||||||||||
D9052 | SD1052 |
| Error step | Stores "0" when errors 80, 81 and 82 occurred. |
| ||||||||||||||||||
| error occurred |
| |||||||||||||||||||||
|
|
|
| Stored the block starting step number when error 83 |
| ||||||||||||||||||
|
|
|
|
|
| ||||||||||||||||||
|
|
|
|
| occurred. |
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
| Transition condition | • Stores the transfer condition number in which error 84 |
| |||||||||||||||||
D9053 | SD1053 |
| Error transition | number where error | occurred in the SFC program in BIN code. |
| |||||||||||||||||
|
|
|
| occurred | Stored "0" when errors 80, 81, 82 and 83 occurred. |
| |||||||||||||||||
|
|
| Error sequence | Sequence step | • Stores the sequence step number of transfer condition |
| |||||||||||||||||
D9054 | SD1054 |
| number where error | and operation output in which error 84 occurred in the |
| ||||||||||||||||||
| step |
| |||||||||||||||||||||
|
|
| occurred | SFC program in BIN code. |
| ||||||||||||||||||
|
|
|
|
| |||||||||||||||||||
|
|
|
|
| • Stores the step number when status latch is executed. |
| |||||||||||||||||
|
|
|
|
| • Stores the step number in a binary value if status latch |
| |||||||||||||||||
|
|
| Status latch |
| is executed in a main sequence program. |
| |||||||||||||||||
|
|
| Status latch | • Stores the block number and the step number if status |
| ||||||||||||||||||
D9055 | SD1055 | SD812 | execution step | latch is executed in a SFC program. |
| ||||||||||||||||||
execution step No. |
| ||||||||||||||||||||||
|
|
| No. |
|
|
| Block No. |
|
|
| Step No. |
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
| (BIN) |
|
|
|
|
| (BIN) |
|
| |||||
|
|
|
|
|
|
|
| Higher 8 bits |
|
|
|
| Lower 8 bits |
|
|
| |||||||
|
|
|
|
|
|
| |||||||||||||||||
|
|
|
|
| • Stores the software version of the internal system in |
| |||||||||||||||||
|
|
|
|
| ASCII code. | The data in the lower byte |
| ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
| Higher byte |
| Lower byte | position is indefinite. |
| ||||||||||||||
|
|
|
|
|
|
| |||||||||||||||||
|
|
|
| Software version of |
| The software version is stored |
| ||||||||||||||||
D9060 | SD1060 | SD392 | Software version |
|
|
|
|
|
|
|
| in the higher byte position. | QnA | ||||||||||
|
|
|
| internal software |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| For version "A", for example, "41H" is stored. |
| ||||||||||||||||||
|
|
|
|
|
| ||||||||||||||||||
|
|
|
|
| Note: The software version of the initial system may |
| |||||||||||||||||
|
|
|
|
|
| differ from the version indicated by the version |
| ||||||||||||||||
|
|
|
|
|
| information printed on the rear of the case. |
| ||||||||||||||||
|
|
| PLC | Data check of serial | • In the |
| |||||||||||||||||
D9072 | SD1072 |
| communications | communication | module, the serial communication module writes/reads |
| |||||||||||||||||
|
|
| check | module | data automatically to make communication checks. |
| |||||||||||||||||
|
|
|
|
| |||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| Number of |
| • Stores the number of empty blocks in the |
| |||||||||||||||||
|
|
| empty blocks in |
|
| ||||||||||||||||||
|
|
|
| communication request registration area to the remote |
| ||||||||||||||||||
D9081 | SD1081 | SD714 | communications | 0 to 32 | QnA | ||||||||||||||||||
terminal module connected to the MELSECNET/MINI- | |||||||||||||||||||||||
|
|
| request |
|
| ||||||||||||||||||
|
|
|
| S3 master unit, A2C or A52G. |
| ||||||||||||||||||
|
|
| registrtion area |
|
| ||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
11 - 90 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|