11 TROUBLESHOOTING

MELSEC-Q

Special Register List (Continued)

 

 

 

 

 

 

Set by

Corresponding

Corresponding

Number

Name

Meaning

 

 

Explanation

ACPU

 

 

(When set)

CPU

 

 

 

 

 

 

D9

 

 

 

 

 

 

 

 

SD381

 

Information from

• Configuration is identical to that for the first module.

 

 

 

Ethernet

2nd module

 

 

 

 

 

 

 

 

 

 

SD382

instruction

Information from

• Configuration is identical to that for the first module.

S (Initial)

New

 

reception

3rd module

 

 

 

 

 

 

 

 

SD383

status

Information from

• Configuration is identical to that for the first module.

 

 

 

 

4th module

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Stores the internal system software version in ASCII code.

 

 

QnA

 

 

 

 

 

The software version is stored

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

in the lower byte position.

 

 

 

 

 

 

Higher byte

Lower

byte The data in the higher byte

 

 

 

SD392

Software

Internal system

 

 

position is indefinite.

S (Initial)

D9060

 

version

software version

For version "A", for example, "41H" is stored.

 

 

 

 

 

 

 

 

Note: The internal system software version may differ from the

 

 

 

 

 

 

version indicated by the version symbol printed on the

 

 

 

 

 

 

case.

 

 

 

 

Multiple PLC

Multiple PLC

• In a multiple PLC system configuration, the PLC number of the

 

 

QCPU function

SD395

host CPU is stored.

S (Initial)

New

number

number

Ver. B or later

 

PLC No. 1: 1, PLC No. 2: 2, PLC No. 3: 3, PLC No. 4: 4

 

 

 

 

 

 

 

 

 

(3) System clocks/counters

 

 

 

 

Set by

Corresponding

Corresponding

Number

Name

Meaning

Explanation

ACPU

(When set)

CPU

 

 

 

 

D9

 

 

 

 

 

 

SD412

1 second

Number of counts in

• Following programmable controller CPU module RUN, 1 is

S (Status

D9022

 

counter

1-second units

added each second

change)

 

 

• Count repeats from 0 to 32767 to -32768 to 0

 

 

 

 

 

 

 

 

 

2n second

2n second clock

• Stores value n of 2n second clock (Default is 30)

 

 

 

SD414

clock

U

New

 

units

• Setting can be made between 1 and 32767

 

 

setting

 

 

 

 

 

 

 

 

 

SD415

2nms clock

2nms clock units

• Stores value n of 2nms clock (Default is 30)

U

New

QCPU

 

setting

 

• Setting can be made between 1 and 32767

 

 

 

SD420

Scan

Number of counts in

• Incremented by 1 for each scan execution after the CPU module

S(Every

New

 

counter

each scan

is set to RUN.

END

 

 

• Count repeats from 0 to 32767 to -32768 to 0

processing)

 

 

 

 

 

 

 

 

Low speed

 

• Incremented by 1 for each scan execution after the CPU module

S(Every

 

 

SD430

Number of counts in

is set to RUN.

New

 

scan

each scan

• Count repeats from 0 to 32767 to -32768 to 0

END

 

 

counter

processing)

 

 

 

 

• Used only for low speed execution type programs

 

 

 

 

 

 

 

 

 

 

 

: Not counted by the scan in an initial execution type program.

11 - 77