8EMC AND LOW VOLTAGE DIRECTIVE

(b)Positioning modules

MELSEC-Q

Precautions to be followed when the machinery conforming to the EMC Directive is configured using the A1SD75P1-S3/A1SD75P2-S3/A1SD75P3- S3 (hereafter referred to as the A1SD75) are described below.

1)When wiring with a 2 m (6.56 ft.) or less cable

Ground the shield section of the external wiring cable with the cable clamp. (Ground the shield at the closest location to the A1SD75 external wiring connector.)

Wire the external wiring cable to the drive unit and external device with the shortest practicable length of cable.

Install the drive unit in the same panel.

Power supply module

A1SD75 module

External wiring connector

Cable clamp

External wiring cable (within 2 m (6.56 ft.))

Drive unit

Power supply module

2)When wiring with cable that exceeds 2 m (6.56 ft.), but is 10 m (32.79 ft.) or less

Ground the shield section of the external wiring cable with the cable clamp. (Ground the shield at the closest location to the A1SD75 external wiring connector.)

Install a ferrite core.

Wire the external wiring cable to the drive unit and external device with

the shortest practicable length of cable.

 

A1SD75 module

 

 

 

 

 

External wiring connector

 

 

 

 

 

 

 

 

 

 

Ferrite core

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cable clamp

 

 

 

 

 

 

 

 

External wiring cable (2 m to 10 m (6.56 ft. to 32.79 ft.))

Drive unit

3)Ferrite core and cable clamp types and required quantities

Cable clamp

Type : AD75CK (Mitsubishi Electric)

Ferrite core

Type : ZCAT3035-1330 (TDK ferrite core)

Required quantity

Cable length

Prepared part

 

Required Qty

 

1 axis

2 axes

3 axes

 

 

Within 2 m (6.56 ft.)

AD75CK

1

1

1

2 m (6.56 ft.) to 10m

AD75CK

1

1

1

(32.79ft.)

ZCAT3035-1330

1

2

3

8 - 6