4 AUXILIARY AND APPLIED FUNCTIONS
4.5 Security FunctionThis function is used to protect the user data of Motion CPU by registering a password. The illegal reading or writing of the user data are prevented by setting a password. Registered password can be changed and deleted.
[Register/Change Password] or [Delete Password] screen is used to register/ change/delete a password. Select from a menu bar to display these screen.
The user data protected in this function are shown below.
"Write Protection" or "Read/Write Protection" can be set every user data.
Operating | User data | Protected contents | |
system software | |||
|
| ||
SV13/SV22 | Motion SFC program | Motion SFC programs (Control code, text) | |
Servo program | Servo programs and program allocation | ||
| |||
SV22 | Mechanical system program | Mechanical system programs | |
Cam data | Cam data | ||
|
Select menu [Online] [Register Password] [Register/Change] to register/change a password.
(1)Procedure for password registration(a)Enter initial registration password in password column, and select registration condition (Write Protection, Read/Write Protection). It leaves in blank for the user data that does not register a password.
(b)Click on [Execute] button to register a password in the Motion CPU.
(c)Select menu [Project] [Save] to save a password after registration in a project.
Refer to Section 4.5.4 for password save.
(2)Procedure for password change(a)Status of password registered in the Motion CPU are displayed.
4 - 21