4 AUXILIARY AND APPLIED FUNCTIONS

4.5 Security Function

This function is used to protect the user data of Motion CPU by registering a password. The illegal reading or writing of the user data are prevented by setting a password. Registered password can be changed and deleted.

[Register/Change Password] or [Delete Password] screen is used to register/ change/delete a password. Select from a menu bar to display these screen.

The user data protected in this function are shown below.

"Write Protection" or "Read/Write Protection" can be set every user data.

Operating

User data

Protected contents

system software

 

 

SV13/SV22

Motion SFC program

Motion SFC programs (Control code, text)

Servo program

Servo programs and program allocation

 

SV22

Mechanical system program

Mechanical system programs

Cam data

Cam data

 

4.5.1 Password registration/change

Select menu [Online] [Register Password] [Register/Change] to register/change a password.

(1)Procedure for password registration

(a)Enter initial registration password in password column, and select registration condition (Write Protection, Read/Write Protection). It leaves in blank for the user data that does not register a password.

(b)Click on [Execute] button to register a password in the Motion CPU.

(c)Select menu [Project] [Save] to save a password after registration in a project.

Refer to Section 4.5.4 for password save.

(2)Procedure for password change

(a)Status of password registered in the Motion CPU are displayed.

4 - 21