3 COMMON PARAMETERS

Setting items for each module (Continued)

 

Module name

Item

Setting range

Initial value

Number of usable modules

 

Q173DCPU

Q172DCPU

 

 

 

 

 

 

 

 

 

 

 

First I/O No.

00 to FF0 (in units of 16 points)

0

 

 

 

 

 

 

Point

0/16/32/64/128/256

16

 

 

 

 

 

 

High-speed data read

Used/Unused

Unused

 

 

QX

 

 

Input module

setting

 

 

 

 

 

 

 

 

 

 

 

 

I/O response time

1/5/10/20/70 ms

10 ms

 

 

 

 

 

 

(setting for high-speed input

 

 

 

 

 

 

(0.1/0.2/0.4/0.6/1 ms)

(0.2 ms)

 

 

 

 

 

 

module in parentheses)

 

 

 

 

QY

 

 

Output module

First I/O No.

00 to FF0 (in units of 16 points)

0

 

 

 

 

Point

0/16/32/64/128/256

16

 

 

 

 

 

 

 

 

 

 

 

 

First I/O No.

00 to FF0 (in units of 16 points)

0

 

 

QH

/

 

Input/Output

Point

0/16/32/64/128/256

16

 

 

 

composite

I/O response time

1/5/10/20/70 ms

10 ms

 

 

QX

Y

 

 

 

 

module

High-speed data read

Used/Unused

Unused

 

 

 

 

 

 

 

 

 

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

First I/O No.

00 to FF0 (in units of 16 points)

0

 

 

 

 

 

 

Input range

4 to 20mA/0 to 20mA/1 to 5V/0 to

4 to 20mA

Total 256

Total 256

 

 

 

 

5V/-10 to 10V/0 to 10V/User range

points or less

points or less

 

 

 

 

 

 

Q6

AD

/

Analogue input

Temperature drift

Used/None

Used

 

 

Q6

AD-

 

module

compensation

 

 

 

 

 

Resolution mode

Normal/High

Normal

 

 

 

 

 

 

 

 

 

 

 

 

 

Normal (A/D conversion)/Offset

Normal

 

 

 

 

 

 

Operation mode

(A/D

 

 

 

 

 

 

gain setting

 

 

 

 

 

 

 

conversion)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

First I/O No.

00 to FF0 (in units of 16 points)

0

 

 

 

 

 

 

Output range

4 to 20mA/0 to 20mA/1 to 5V/0 to

4 to 20mA

 

 

 

 

 

 

5V/-10 to 10V/User range

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HOLD/CLEAR function

CLEAR only

CLEAR

 

 

Q6

DA

/

Analogue

 

Normal (Asynchronous)/

Normal

 

 

Output mode

(Asyn-

 

 

Q6

DA-

 

output module

Synchronous output

 

 

 

 

 

 

 

 

chronous)

 

 

 

 

 

 

Resolution mode

Normal/High

Normal

 

 

 

 

 

 

 

Normal (D/A conversion)/

Normal

 

 

 

 

 

 

Operation mode

(D/A

 

 

 

 

 

 

Offset gain setting

 

 

 

 

 

 

 

conversion)

 

 

 

 

 

 

 

 

 

 

3 - 13