4 AUXILIARY AND APPLIED FUNCTIONS

4.9Servo Parameter Reading Function

(1)When the servo parameters are changed, the Motion CPU will be automatically read the servo parameters and reflected them to the servo parameter storage area in the Motion CPU. Therefore, an operation to read servo parameters is unnecessary in the following cases.

(a)The parameters are changed by auto tuning.

(b)The parameters are changed by connecting directly MR Configurator to the servo amplifier.

POINT

If the power supply of Multiple CPU system is turned off/reset or the power supply of servo amplifier is turned off immediately after change, it may not be reflected.

(2)After executing the servo parameter reading function, when it needs to reflect the servo parameters changed to the MT Developer, read the servo parameters from the Motion CPU and save data.

4 - 34