4 AUXILIARY AND APPLIED FUNCTIONS

4.1.2 Limit output setting data

Limit output data list are shown below.

Up to 32 points of output devices can be set.

(The following items of No.1 to No.5 are set together as one point.)

No.

Item

Setting range

 

Fetch

Refresh

Remarks

 

cycle

cycle

 

 

 

 

 

 

 

 

1

Output device

Bit device (X, Y, M, B, U

\G)

 

Operation

 

 

cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motion control data/ word device (D, W, #,

 

 

 

2

Watch data

 

U \G, absolute address)

 

 

 

 

 

 

(16-bit integer type/32-bit integer type/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

64-bit floating-point type)

 

 

 

 

 

3

ON region

 

ON Value

Word device (D, W, #, U

\G)/constant (K, H)

 

 

 

setting

 

OFF Value

Word device (D, W, #, U

\G)/constant (K, H)

Operation

 

 

 

 

 

 

 

 

 

 

 

 

ON : Enable

 

Output enable/disable

Bit device (X, Y, M, B, F, SM, U

\G)/ none

cycle

4

 

OFF : Disable

bit

 

(default)

 

 

 

 

 

 

 

 

 

 

None : Always enable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

None : No forced

5

Forced output bit

Bit device (X, Y, M, B, F, SM, U

\G)/ none

 

 

outputs are

(default)

 

 

 

 

always made

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(OFF status)

(1)Output device

(a)Set the bit device which outputs the ON/OFF signal toward the preset watch data.

(b)As the output device, the following devices can be used.

Item

Device No. setting range

Input relay (Note-1)

X0 to X1FFF

Output relay (Note-2)

Y0 to Y1FFF

Internal relay (Note-3)

M0 to M8191

Link relay

B0 to B1FFF

Multiple CPU area device

U \G10000.0 to U \G (10000+p-1).F (Note-4),(Note-5)

(Note-1) : PX is write-disabled and it cannot be used as the output device. For X, only the free No. of the input card non-loading can be used.

(Note-2) : The real output device range (PY) is also included.

(Note-3) : M2001 to M2032 cannot be used to the output device.

Be careful because it affect a positioning operation, when the positioning dedicated devices are set.

(Note-4) : "p" indicates the user setting area points of the Multiple CPU high speed transmission area for the each CPU.

(Note-5) : Only device of the self CPU can be used.

4 - 4