1 OVERVIEW

(b) Motion SFC Performance Specifications

 

Item

 

 

 

Q173DCPU/Q172DCPU

 

 

 

 

 

 

 

Code total

 

 

 

 

 

(Motion SFC chart + Operation control

543k bytes

Motion SFC program capacity

+ Transition)

 

 

 

 

Text total

 

 

 

484k bytes

 

(Operation control + Transition)

 

 

 

Number of Motion SFC programs

256 (No.0 to 255)

 

Motion SFC chart size/program

Up to 64k bytes (Included Motion SFC chart comments)

Motion SFC program

Number of Motion SFC steps/program

Up to 4094 steps

Number of selective branches/branch

255

 

 

Number of parallel branches/branch

255

 

Parallel branch nesting

 

Up to 4 levels

 

Number of operation control programs

4096 with F(Once execution type) and FS(Scan execution type)

 

combined. (F/FS0 to F/FS4095)

 

 

 

 

 

 

Number of transition programs

4096(G0 to G4095)

Operation control program

Code size/program

 

Up to approx. 64k bytes (32766 steps)

(F/FS)

Number of blocks(line)/program

Up to 8192 blocks (in the case of 4 steps(min)/blocks)

/

Number of characters/block

Up to 128 (comment included)

Transition program

Number of operand/block

Up to 64 (operand: constants, word device, bit devices)

(G)

( ) nesting/block

 

Up to 32 levels

 

Descriptive

Operation control program

Calculation expression/bit conditional expression

 

 

 

Calculation expression/bit conditional expression/

 

expression

Transition program

 

comparison conditional expression

 

 

 

 

 

 

Number of multi execute programs

Up to 256

 

Number of multi active steps

Up to 256 steps/all programs

 

 

Normal task

 

Execute in main cycle of Motion CPU

 

 

Event task

Fixed cycle

Execute in fixed cycle

 

 

(0.88ms, 1.77ms, 3.55ms, 7.11ms, 14.2ms)

Execute specification

 

(Execution

 

Executed

External

Execute when input ON is set among interrupt module QI60

 

can be

 

task

masked.)

interrupt

(16 points).

 

 

PLC interrupt

Execute with interrupt instruction (D(P).GINT) from PLC CPU.

 

 

 

 

 

 

NMI task

 

Execute when input ON is set among interrupt module QI60

 

 

 

(16 points).

 

 

 

 

 

 

Internal relays

(M)

8192 points

 

Link relays

 

 

(B)

8192 points

Number of devices

Annunciators

(F)

2048 points

Special relays

(SM)

2256 points

(Device In the Motion CPU

Data registers

(D)

8192 points

only)

Link registers

(W)

8192 points

(Included the positioning

Special registers

(SD)

2256 points

dedicated device)

Motion registers

(#)

8736 points

 

 

Coasting timers

(FT)

1 point (888µs)

 

Multiple CPU area devices (U \G)

Up to 14336 points usable (Note)

(Note): Usable number of points changes according to the system settings.

1 - 7