4 AUXILIARY AND APPLIED FUNCTIONS
4. AUXILIARY AND APPLIED FUNCTIONS
4.1 Limit Switch Output Function
This function is used to output the ON/OFF signal corresponding to the data range of the watch data set per output device.
Motion control data or optional word data can be used as watch data. (Refer to Section "4.1.2 Limit output setting data" for details.) A maximum output device for 32 points can be set regardless of the number of axes.
4.1.1 Operations
(1) ON output to an output device is made while the watch data value is in the ON output region set with (ON Value) and (OFF Value) in this function.
(a) (ON Value), (OFF Value) and watch data value are handled as signed data.
ON output region where an ON output is made to the output device is4 governed by the magnitude relationship between (ON Value) and (OFF
Value) as indicated below.
Relationship between (ON Value) and | ON output region | |
(OFF Value) | ||
| ||
(ON Value) < (OFF Value) | (ON Value) <= (watch data value) < (OFF Value) | |
(ON Value) > (OFF Value) | (ON Value) <= (watch data value) | |
(Watch data value) < (OFF Value) | ||
| ||
(ON Value) = (OFF Value) | Output OFF in whole region |
1) (ON Value) < (OFF Value)
Output device
ON region setting
Watch data value
| ON |
OFF | OFF |
| |
OFF Value |
|
ON Value |
|
(ON Value)(Watch data value)(OFF Value)
2) (ON Value) > (OFF Value)
ON | ON |
Output device | OFF |
ON Value
ON region setting
OFF Value
Watch data value
(Watch data value) (OFF Value) | (ON Value) |
| (Watch data value) |
|
4 - 1