4AUXILIARY AND APPLIED FUNCTIONS
(5)Forced output bit(a)Set the "forced output bit" when you want to forcibly provide the limit switch outputs during operation.
1)The following control is exercised.
Output enable/disable bit | Control description | |
Without setting | Limit switch outputs are turned ON/OFF on the basis of | |
| OFF | the "output enable/disable bit" and ON region setting |
With setting | (ON Value, OFF Value). | |
| ON | Limit switch outputs are turned ON. |
(b) Usable devices
Item | Device No. setting range |
Input relay | X0 to X1FFF |
Output relay | Y0 to Y1FFF |
Internal relay | M0 to M8191 |
Link relay | B0 to B1FFF |
Annunciator | F0 to F2047 |
Special relay | SM0 to SM1999 |
Multiple CPU area device | U \G10000.0 to U \G |
POINT
Refer to Chapter 2 for the user setting area points of the Multiple CPU high speed transmission area.
4 - 7