APPENDICES

Table 1.1 Special relay list (Continued)

No.

Name

 

Meaning

Details

Set by

Remark

 

(When set)

 

 

 

 

 

 

 

SM243

No.4 CPU resetting

OFF : CPU No.4 reset cancel

• Goes OFF when reset of the CPU No.4 is cancelled.

 

 

 

 

ON

: CPU No.4 resetting

 

 

 

 

 

OFF : CPU No.1 normal

• Goes OFF when the CPU No.1 is normal. (Including a

 

 

SM244

No.1 CPU error

ON

: CPU No.1 during stop

continuation error)

 

 

 

 

 

error

• Comes ON when the CPU No.1 is during stop error. (Note-2)

 

 

 

 

OFF : CPU No.2 normal

• Goes OFF when the CPU No.2 is normal. (Including a

 

 

SM245

No.2 CPU error

ON

: CPU No.2 during stop

continuation error)

S (Change status)

 

 

 

 

error

• Comes ON when the CPU No.2 is during stop error. (Note-2)

 

 

 

OFF : CPU No.3 normal

• Goes OFF when the CPU No.3 is normal. (Including a

 

 

SM246

No.3 CPU error

ON

: CPU No.4 during stop

continuation error)

 

 

 

 

 

error

• Comes ON when the CPU No.3 is during stop error. (Note-2)

 

 

 

 

OFF : CPU No.4 normal

• Goes OFF when the CPU No.4 is normal. (Including a

 

 

SM247

No.4 CPU error

ON

: CPU No.4 during stop

continuation error)

 

 

 

 

 

error

• Comes ON when the CPU No.4 is during stop error. (Note-2)

 

 

SM400

Always ON

ON

 

 

• Normally is ON.

 

 

 

 

 

 

OFF

 

 

S (Main processing)

 

 

 

 

 

 

 

SM401

Always OFF

ON

 

 

• Normally is OFF.

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

: PCPU READY

• When the PLC ready flag (M2000) turn OFF to ON, the

 

 

 

 

fixed parameters, servo parameters and limit switch output

 

 

 

PCPU READY

 

completion

 

 

SM500

 

data, etc., are checked, and if no error is detected, this flag

 

 

complete

OFF : PCPU READY

 

 

 

 

 

incompletion

turns ON.

 

 

 

 

 

• Turn OFF with PLC ready flag (M2000) OFF.

S (Request)

 

 

 

 

 

 

 

 

 

 

 

 

• Judge whether TEST mode ON or not using MT Developer.

 

 

SM501

Test mode ON

ON

: TEST mode ON

• If the TEST mode is not established by TEST mode request

 

 

OFF : Except TEST mode

using MT Developer, the TEST mode request error flag

 

 

 

 

 

 

 

 

 

 

 

(SM510) turns ON.

 

 

SM502

External forced stop

ON

: Forced stop OFF

• Confirm forced stop ON/OFF.

S (Operation cycle)

 

input

OFF : Forced stop ON

 

 

 

ON

: Digital oscilloscope is

 

 

 

SM503

Digital oscilloscope

 

stop

• Confirm the execution of digital oscilloscope using MT

S (Change status)

 

 

executing

OFF : Digital oscilloscope is

Developer.

 

 

 

 

 

executing

 

 

 

 

 

 

 

 

• Turn ON if the TEST mode is not established by TEST mode

 

 

SM510

TEST mode request

ON

: Abnormal

request using MT Developer.

 

 

error

OFF : Normal

• When this relay is ON, the error content is stored in the

 

 

 

 

 

 

 

TEST mode request error register (SD510, SD511).

 

 

 

 

 

 

 

• Turn ON when a "watchdog timer error" is detected by the

 

 

 

 

 

 

 

Motion CPU self-diagnosis function.

 

 

SM512

Motion CPU WDT

ON

: Abnormal

When the Motion CPU detects a WDT error, it executes an

 

 

error

OFF : Normal

immediate stop without deceleration of the operating axes.

 

 

 

 

 

 

 

• The error cause is stored in the "Motion CPU WDT error

 

 

 

 

 

 

 

cause (SD512)".

 

 

 

 

ON

: At least one D714 to

• Judge whether normal/abnormal of the register for manual

 

 

 

Manual pulse

 

D719 setting is

pulse generator axis setting register (D714 to D719).

 

 

SM513

generator axis setting

 

abnormal.

• When this relay is ON, the error content is stored in the

 

 

 

error

OFF : All D714 to D719

manual pulse generator axis setting error register (SD513

S (Occur an error)

 

 

 

 

settings are normal.

to SD515).

 

 

 

 

 

 

 

• Judge whether normal/abnormal of the positioning data of

 

 

 

Servo program

ON

: Abnormal

servo program(K) specified with the Motion SFC program,

 

 

SM516

and if error is detected this flag turns ON.

 

 

setting error

OFF : Normal

 

 

 

 

 

 

 

• The content of a servo program setting error is stored at

 

 

 

 

 

 

 

SD516, SD517.

 

 

 

Over heat warning

OFF : Normal

• Turn ON when the temperature of Motion CPU module

 

 

SM526

becomes specified value 85[°C] (185[°F]) or more.

 

 

latch

ON

: Abnormal

 

 

 

 

 

 

 

Remains ON even if normal status is restored.

 

 

 

 

 

 

 

• Turn ON when the temperature of Motion CPU module

 

 

SM527

Over heat warning

OFF : Normal

becomes specified value 85[°C] (185[°F]) or more.

 

 

ON

: Abnormal

Turn OFF when the temperature of Motion CPU module

 

 

 

 

 

 

 

 

 

 

 

returns to normal.

 

 

APP - 3