Table 1.1 Special relay list (Continued)No. | Name |
| Meaning | Details | Set by | Remark | |
| (When set) | ||||||
|
|
|
|
|
|
| |
SM243 | No.4 CPU resetting | OFF : CPU No.4 reset cancel | • Goes OFF when reset of the CPU No.4 is cancelled. |
|
| ||
|
| ON | : CPU No.4 resetting |
|
|
| |
|
| OFF : CPU No.1 normal | • Goes OFF when the CPU No.1 is normal. (Including a |
|
| ||
SM244 | No.1 CPU error | ON | : CPU No.1 during stop | continuation error) |
|
| |
|
|
| error | • Comes ON when the CPU No.1 is during stop error. |
|
| |
|
| OFF : CPU No.2 normal | • Goes OFF when the CPU No.2 is normal. (Including a |
|
| ||
SM245 | No.2 CPU error | ON | : CPU No.2 during stop | continuation error) | S (Change status) |
| |
|
|
| error | • Comes ON when the CPU No.2 is during stop error. |
| ||
|
| OFF : CPU No.3 normal | • Goes OFF when the CPU No.3 is normal. (Including a |
|
| ||
SM246 | No.3 CPU error | ON | : CPU No.4 during stop | continuation error) |
|
| |
|
|
| error | • Comes ON when the CPU No.3 is during stop error. |
|
| |
|
| OFF : CPU No.4 normal | • Goes OFF when the CPU No.4 is normal. (Including a |
|
| ||
SM247 | No.4 CPU error | ON | : CPU No.4 during stop | continuation error) |
|
| |
|
|
| error | • Comes ON when the CPU No.4 is during stop error. |
|
| |
SM400 | Always ON | ON |
|
| • Normally is ON. |
|
|
|
|
|
| ||||
OFF |
|
| S (Main processing) |
| |||
|
|
|
|
|
| ||
SM401 | Always OFF | ON |
|
| • Normally is OFF. |
| |
|
|
|
| ||||
OFF |
|
|
|
| |||
|
|
|
|
|
|
| |
|
| ON | : PCPU READY | • When the PLC ready flag (M2000) turn OFF to ON, the |
|
| |
|
| fixed parameters, servo parameters and limit switch output |
|
| |||
| PCPU READY |
| completion |
|
| ||
SM500 |
| data, etc., are checked, and if no error is detected, this flag |
|
| |||
complete | OFF : PCPU READY |
|
| ||||
|
|
| incompletion | turns ON. |
|
| |
|
|
| • Turn OFF with PLC ready flag (M2000) OFF. | S (Request) |
| ||
|
|
|
|
|
| ||
|
|
|
|
| • Judge whether TEST mode ON or not using MT Developer. |
|
|
SM501 | Test mode ON | ON | : TEST mode ON | • If the TEST mode is not established by TEST mode request |
|
| |
OFF : Except TEST mode | using MT Developer, the TEST mode request error flag |
|
| ||||
|
|
|
| ||||
|
|
|
|
| (SM510) turns ON. |
|
|
SM502 | External forced stop | ON | : Forced stop OFF | • Confirm forced stop ON/OFF. | S (Operation cycle) |
| |
input | OFF : Forced stop ON |
| |||||
|
| ON | : Digital oscilloscope is |
|
|
| |
SM503 | Digital oscilloscope |
| stop | • Confirm the execution of digital oscilloscope using MT | S (Change status) |
| |
| executing | OFF : Digital oscilloscope is | Developer. |
|
| ||
|
|
| executing |
|
|
| |
|
|
|
|
| • Turn ON if the TEST mode is not established by TEST mode |
|
|
SM510 | TEST mode request | ON | : Abnormal | request using MT Developer. |
|
| |
error | OFF : Normal | • When this relay is ON, the error content is stored in the |
|
| |||
|
|
|
|
| TEST mode request error register (SD510, SD511). |
|
|
|
|
|
|
| • Turn ON when a "watchdog timer error" is detected by the |
|
|
|
|
|
|
| Motion CPU |
|
|
SM512 | Motion CPU WDT | ON | : Abnormal | When the Motion CPU detects a WDT error, it executes an |
|
| |
error | OFF : Normal | immediate stop without deceleration of the operating axes. |
|
| |||
|
|
|
|
| • The error cause is stored in the "Motion CPU WDT error |
|
|
|
|
|
|
| cause (SD512)". |
|
|
|
| ON | : At least one D714 to | • Judge whether normal/abnormal of the register for manual |
|
| |
| Manual pulse |
| D719 setting is | pulse generator axis setting register (D714 to D719). |
|
| |
SM513 | generator axis setting |
| abnormal. | • When this relay is ON, the error content is stored in the |
|
| |
| error | OFF : All D714 to D719 | manual pulse generator axis setting error register (SD513 | S (Occur an error) |
| ||
|
|
| settings are normal. | to SD515). |
|
| |
|
|
|
|
| • Judge whether normal/abnormal of the positioning data of |
|
|
| Servo program | ON | : Abnormal | servo program(K) specified with the Motion SFC program, |
|
| |
SM516 | and if error is detected this flag turns ON. |
|
| ||||
setting error | OFF : Normal |
|
| ||||
|
|
|
|
| • The content of a servo program setting error is stored at |
|
|
|
|
|
|
| SD516, SD517. |
|
|
| Over heat warning | OFF : Normal | • Turn ON when the temperature of Motion CPU module |
|
| ||
SM526 | becomes specified value 85[°C] (185[°F]) or more. |
|
| ||||
latch | ON | : Abnormal |
|
| |||
|
|
|
|
| Remains ON even if normal status is restored. |
|
|
|
|
|
|
| • Turn ON when the temperature of Motion CPU module |
|
|
SM527 | Over heat warning | OFF : Normal | becomes specified value 85[°C] (185[°F]) or more. |
|
| ||
ON | : Abnormal | Turn OFF when the temperature of Motion CPU module |
|
| |||
|
|
|
| ||||
|
|
|
|
| returns to normal. |
|
|