4AUXILIARY AND APPLIED FUNCTIONS

(b)Operation procedure to connect

1)Turn ON the power supply of the servo amplifier.

2)Set "-10: Connect command" in SD803.

3)Check that "-1: Connect execute waiting" is set in SD508. (Connect execute waiting)

4)Set "-2: Connect execute command" in SD803.

5)Check that SD508 is "0: Connect command accept waiting" is set in SD508.

(Completion of connection)

6)Resume operation of servo amplifier after verifying the servo ready status (M2415+20n) is ON.

(4)Flow for device value at connect/disconnect operation is shown below.

(a)Disconnect operation

 

 

 

 

Disconnect command

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Axis No. of servo amplifier

 

Disconnect execute

 

 

Disconnect

 

 

 

 

 

to disconnect)

 

 

 

command

 

 

 

 

command clear

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Command

SD803

0

 

 

 

 

 

1 to 32

 

 

 

-2

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Monitor

SD508

0

 

 

-1

 

 

 

 

-2

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Disconnect command

 

 

 

Disconnect execute

 

 

 

 

Disconnect

 

 

 

Completion of

 

 

accept waiting

 

 

 

waiting

 

 

 

 

processing execute

 

 

 

disconnection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(b)

Connect operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connect command

 

Connect execute command

 

 

Connect command clear

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Command

SD803

0

 

 

-10

 

 

 

 

-2

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Monitor

SD508

0

 

 

-1

 

 

 

 

-2

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connect command

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Completion of

 

 

accept waiting

 

 

 

Connect execute waiting

 

Connect processing execute

 

connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 - 38