3 COMMON PARAMETERS
3.3 Servo ParametersThe servo parameters control the data fixed by the specifications of the servo amplifier and servomotor controlled in the parameter set for each axis and the control of the servomotor.
The servo parameters are set by the Setup software (MR Configurator).
Refer to the "Servo amplifier Instruction Manual" for details of the servo parameters.
Refer to the help for handling of MR Configurator.
Instruction Manual list is shown below.
Servo amplifier type | Instruction manual name | ||
B | |||
Fully closed loop control | |||
|
|
No. | Symbol |
| Name | Initial value | Unit |
PA01 | — | For manufacturer setting |
| 0000h | — |
PA02 | REG | Regenerative brake option |
| 0000h | — |
PA03 | ABS | Absolute position detection system |
| 0000h | — |
PA04 | AOP1 | Function selection |
| 0000h | — |
PA05 |
|
|
| 0 |
|
PA06 | — | For manufacturer setting |
| 1 | — |
PA07 |
|
|
| 1 |
|
PA08 | ATU | Auto tuning mode |
| 0001h | — |
PA09 | RSP | Auto tuning response |
| 12 | — |
PA10 | INP |
| 100 | PLS | |
PA11 |
|
|
| 1000.0 |
|
PA12 | — | For manufacturer setting |
| 1000.0 | — |
PA13 |
|
|
| 0000h |
|
PA14 | POL | Rotation direction selection |
| 0 | — |
PA15 | ENR | Encoder output pulse |
| 4000 | PLS/rev |
PA16 |
|
|
| 0 |
|
PA17 | — | For manufacturer setting |
| 0000h | — |
PA18 |
| 0000h | |||
|
|
|
| ||
PA19 |
|
|
| 000Bh |
|
POINTS
(1)When the items marked "" in the above table has changed, make the Multiple CPU system reset or power supply OFF to ON. And, once turn OFF the servo amplifier power supply and then turn ON it again.
3 - 19