APPENDICES

Table 1.2 Special register list (Continued)

No.

Name

Meaning

 

Details

Set by

Remark

 

(When set)

 

 

 

 

 

 

SD395

Multiple CPU No.

Multiple CPU No.

• CPU No. of the self CPU is stored.

S (Initial processing)

 

 

 

 

• The information (Real mode axis: 0/Except real mode axis: 1) used as a real

 

 

 

Real mode axis

 

mode axis at the time of switching from real mode to virtual mode is stored.

 

 

SD500

Real mode axis

SD500 : b0 to b15 (Axis 1 to 16)

S (At virtual mode

 

SD501

information

information register

SD501 : b0 to b15 (Axis 17 to 32)

transition)

 

 

register

 

• The real mode axis information does not change at the time of switching from

 

 

 

 

 

 

 

 

 

 

virtual mode to real mode

 

 

 

 

 

• The loading status (loading: 1/non-loading: 0) of the servo amplifier checked

 

 

 

 

 

in initial process, and stored as the bit data.

 

 

SD502

Servo amplifier

Servo amplifier

SD502 : b0 to b15 (Axis 1 to 16)

 

 

SD503

loading

loading information

SD503 : b0 to b15 (Axis 17 to 32)

S (Initial processing)

 

 

information

 

• The axis which turned from non-loading to loading status after power-on is

 

 

 

 

 

handled as loaded. (However, the axis which turned from loading to non-

 

 

 

 

 

loading status remains as loaded.)

 

 

SD504

Real mode/virtual

Real mode /virtual

• When a mode switching error occurs in real-to-virtual or virtual-to-real

 

 

SD505

mode switching

mode switching

mode switching, or a mode continuation error occurs in the virtual mode, its

S (Occur an error)

 

SD506

error information

error code

error information is stored.

 

 

 

 

 

• This signal is used to temporarily suspend SSCNET communication while

 

 

 

 

 

servo amplifiers and/or SSCNET cables after Axis 1 are exchanged with the

 

 

 

Connect/

Connect/

power supply ON in a Multiple CPU system.

 

 

 

SD508 stores the command status for "accept waiting" or "execute waiting"

 

 

SD508

Disconnect

disconnect of

 

 

during this process.

 

 

 

(Status)

SSCNET

 

 

 

 

0 : Connect/disconnect command accept waiting

 

 

 

 

 

 

 

 

 

 

 

 

-1 : Connect/disconnect execute waiting

S (Main processing)

 

 

 

 

 

-2 Connect/disconnect executing

 

 

 

 

It is operating in

 

 

 

 

SD510

Test mode

requirement error

• Each axis is stopping: 0/Operating: 1, information is stored as a bit data.

 

 

occurrence of the

SD510 : b0 to b15 (Axis 1 to Axis 16)

 

 

SD511

request error

 

 

test mode, axis

SD511 : b0 to b15 (Axis 17 to Axis 32)

 

 

 

 

 

 

 

 

information

 

 

 

 

 

 

 

• The following error codes are stored in SD512.

 

 

 

 

 

 

1: S/W fault 1

 

 

 

 

 

 

2: Operation cycle over

 

 

 

 

 

 

3: Q bus WDT error

 

 

 

Motion CPU

Error meaning of

 

4: WDT error

 

 

SD512

201 to 215: Q bus H/W fault

 

 

WDT error cause

WDT error occurs

 

 

 

 

 

250 to 253: Servo amplifier interface H/W fault

 

 

 

 

 

 

300: S/W fault 3

 

 

 

 

 

 

301: 15 CPSTART instructions of 8 or more points were started

 

 

 

 

 

 

simultaneously.

 

 

 

 

 

 

303: S/W fault 4

 

 

 

 

 

• Contents of the manual pulse generator axis setting error is stored when the

 

 

 

 

 

manual pulse generator axis setting error flag (SM513) turn on.

S (Occur an error)

 

 

 

 

(Normal: 0/Setting error: 1)

 

 

SD513

Manual pulse

Manual pulse

SD513 : The manual pulse generator axis setting error is stored in b0 to b2

 

 

generator axis

 

(P1 to P3).

 

 

SD514

generator axis

 

 

 

setting error

 

The smoothing magnification setting is stored in b3 to b5 (P1 to P3).

 

 

SD515

setting error

 

 

 

information

SD514 : One pulse input magnification setting error is stored in b0 to b15

 

 

 

 

 

 

 

 

 

 

(axis 1 to axis 16).

 

 

 

 

 

SD515 : One pulse input magnification setting error is stored in b0 to b15

 

 

 

 

 

 

(axis 17 to axis 32).

 

 

SD516

Error program

Error program No.

• When the servo program setting error flag (SM516) turns on, the erroneous

 

 

No.

of servo program

servo program No. will be stored.

 

 

SD517

Error item

Error code of servo

• When the servo program setting error flag (SM516) turns on, the error code

 

 

 

information

program

corresponding to the erroneous setting item will be stored.

 

 

SD520

Scan time

Scan time

• Main cycle is stored in the unit 1ms.

 

 

(1ms units)

Setting range (0 to 65535[ms])

 

 

 

 

S (Main processing)

 

SD521

Maximum scan

Maximum scan

• The maximum value of the main cycle is stored in the unit 1ms.

 

 

 

time

time (1ms units)

Setting range (0 to 65535[ms])

 

 

APP - 9