4AUXILIARY AND APPLIED FUNCTIONS
(3)ON region setting(a)The data range which makes the output device turn ON/OFF toward the watch data.
(b)The following devices can be used as the ON Value and OFF Value of the data range.
The data type of device/constant to be set is the same as the type of watch data.
Item | Device No. setting range |
Data register | D0 to D8191 |
Link register | W0 to W1FFF |
Motion register | #0 to #7999 |
Multiple CPU area device | U \G10000 to U \G |
Constant | Hn/Kn |
(a)Set the status of output enable/disable bit when the limit switch output is forbidden during operation.
1)The following control is exercised.
Output enable/disable bit | Control description | ||
Without setting | Limit switch output is turned ON/OFF based on the ON | ||
(always enable) | |||
region setting (ON Value, OFF Value). | |||
With setting | ON (enable) | ||
| |||
OFF (disable) | Limit switch output is turned OFF. | ||
|
(b) Usable devices
|
| Item | Device No. setting range |
| Input relay | X0 to X1FFF | |
| Output relay | Y0 to Y1FFF | |
| Internal relay | M0 to M8191 | |
| Link relay | B0 to B1FFF | |
| Annunciator | F0 to F2047 | |
| Special relay | SM0 to SM1999 | |
| Multiple CPU area device | U \G10000.0 to U \G | |
: The real input range(PX) is included. | |||
: The real input range(PY) is included. | |||
: "p" indicates the user setting area points of the Multiple CPU high speed | |||
|
| transmission area for the each CPU. |
4 - 6