3 COMMON PARAMETERS
Servo external signal (Upper stroke limit/Lower stroke limit/Stop signal/Proximity dog) can be selected for every axis from the following two methods.
(a)Q172DLX Servo external signals interface module use
Set the servo external signals interface module, and set axis No. as the "External signal setting" in the system setting.
(b)Servo amplifier input device use
Set "Amplifier input valid" as the external signal input setting in the "Amplifier setting" of system setting.
There are following restrictions to use.
•Count type home position return cannot be used.
•Speed/position switching control cannot be executed.
•Stop signal (STOP) cannot be used.
The correspondence of external signal and input device is shown below.
External signals | Input device (CN3) (Note) |
Upper stroke limit (FLS) | DI1 |
Lower stroke limit (RLS) | DI2 |
Proximity dog (DOG) | DI3 |
(Note): Refer to the
Set the external signal setting in the "Input Filter Setting".
3 - 14