APPENDICES

APPENDIX 4.3 Differences of each mode

 

 

(1)

Motion SFC

 

 

 

 

Table 4.9 Differences in Motion SFC mode

 

 

 

 

 

Item

 

 

Q173DCPU/Q172DCPU

Q173HCPU/Q172HCPU

Motion SFC program executing flag

 

 

X, Y, M, B, U

\G

Operation control/transition control usable device

 

D, W, U \G, SD, #, FT

D, W, Special D, #, FT

(Word device)

 

 

 

 

 

 

 

Operation control/transition control usable device

 

X, PX, Y, PY, M, U \G

. , B, F, SM

X, PX, Y, PY, M, L, B, F, Special M

(Bit device)

 

 

 

 

 

 

 

 

(2)

Virtual mode

 

 

 

 

Table 4.10 Differences in Virtual mode

 

 

 

 

 

 

 

Item

 

Q173DCPU/Q172DCPU

Q173HCPU/Q172HCPU

Internal relay/

 

M4640 to M4687

Device area of 9 axes or more is usable as user

Device area of 9 axes or more is unusable in the

 

M5440 to M5487

Data register

 

devices in the Q172DCPU.

Q172HCPU.

 

D1120 to D1239

 

 

 

 

 

Clutch status

 

 

 

Optional device

M2160 to M2223

 

 

(Set for M2160 to M2223 are also usable.)

 

 

 

 

Cam axis command signals

 

Optional device

 

(Cam/ball screw switching

 

M5488 to M5519

(Set for M5488 to M5519 are also usable.)

command)

 

 

 

 

 

 

 

 

Smoothing clutch complete signals

 

Optional device

M5520 to M5583

(Set for M5520 to M5583 are also usable.)

 

 

 

 

Real mode axis information register

 

SD500, SD501

D790, D791

Indirect setting devices of

 

D0 to D8191

D800 to D3069, D3080 to D8191

 

W0 to W1FFF

W0 to W1FFF

mechanical system program

 

 

#0 to #7999

(Word device)

 

 

 

 

 

U

\G10000 to U \G(10000 + p –1 ) (Note-1)

 

 

 

 

 

 

 

X0 to X1FFF

X0 to X1FFF

 

 

 

 

Y0 to Y1FFF

Y0 to Y1FFF

Indirect setting devices of

 

M0 to M8191

M/L0 to M/L8191

mechanical system program

 

M9000 to M9255

(Bit device)

 

 

 

B0 to B1FFF

B0 to B1FFF

 

 

 

 

F0 to F2047

F0 to F2047

 

 

 

U

\G10000.0 to U \G(10000 + p –1 ).F (Note-1)

Speed change ratio of speed

 

Upper limit value : 0 to 65535

Upper limit value : 1 to 10000

change gear

 

 

 

Lower limit value : 0 to 65535

Lower limit value : 1 to 10000

Permissible droop pulse value of

 

1 to 1073741824 [PLS]

1 to 65535[100PLS]

output module

 

 

 

 

 

 

 

 

(Note-1) : "p" indicates user setting area points of Multiple CPU high speed transmission area in each CPU.

POINT

Refer to Chapter 2 for number of user setting area points of Multiple CPU high speed transmission area.

APP - 35