Timer Interface A (TIMA)
I/O Registers
MC68HC908MR16/MC68HC908MR32 — Rev. 4.0 Advance Information
MOTOROLA Timer Interface A (TIMA) 217
11.8.3 TIMA Counter Modulo Registers
The read/write TIMA modulo registers contain the modulo value for the
TIMA counter. When the TIMA counter reaches the modulo value, the
overflow flag (TOF) becomes set, and the TIMA counter resumes
counting from $0000 at the next clock. Writing to the high byte
(TAMODH) inhibits the TOF bit and overflow interrupts until the low byte
(TAMODL) is written. Reset sets the TIMA counter modul o r eg ister s.
NOTE: Reset the TIMA counter before writing to the TIMA counter mo dulo
registers.
11.8.4 TIMA Channel Status and Control Registers
Each of the TIMA channel status and control registers:
Flags input captures and output compares
Enables input capture and output compare interrupts
Selects input capture, output compare, or PWM operation
Selects high, low, or toggling output on output compare
Selects rising edge, falling edge, or any edge as the active input
capture trigger
Register Name and Address: TAMODH — $0011
Bit 7654321Bit 0
Read: Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8
Write:
Reset:11111111
Register Name and Address: TAMODL — $0012
Bit 7654321Bit 0
Read: Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Write:
Reset:11111111
Figure 11-6. TIMA Counter Modulo Registers
(TAMODH and TAMODL)