Timer Interface B (TIMB)
I/O Registers
MC68HC908MR16/MC68HC908MR32 — Rev. 4.0 Advance Information
MOTOROLA Timer Interface B (TIMB) 243
When CHxIE = 0, clear CHxF by reading TIMB channel x status and
control register with CHxF set, and then writing a logic 0 to CHxF. If
another interrupt request occurs before the clearing sequence is
complete, then writing logic 0 to CHxF has no effect. Therefore, an
interrupt request cannot be lost due to inadvertent clearing of CHxF.
Reset clears the CHxF bit. Writing a logic 1 to CHxF has no effect.
1 = Input capture or output compare on channel x
0 = No input capture or output compare on channel x
CHxIE — Channel x Interrupt Enable Bit
This read/write bit enables TIMB CPU interrupts on channel x.
Reset clears the CHxIE bit.
1 = Channel x CPU interrupt requests enabled
0 = Channel x CPU interrupt requests disabled
MSxB — Mode Select Bit B
This read/write bit selects buffered output compare/PWM operation.
MSxB exists only in the TIMB channel 0.
Setting MS0B disables the channel 1 status and control register and
reverts TCH1B to general-purpose I/O.
Reset clears the MSxB bit.
1 = Buffered output compare/PWM operation enabled
0 = Buffered output compare/PWM operation disabled
MSxA — Mode Select Bit A
When ELSxB:A ≠ 00, this read/write bit selects either input capture
operation or unbuffered output compare/PWM operation.
See Table 12-2.
1 = Unbuffered output compare/PWM operation
0 = Input capture operation
When ELSxB:A = 00, this read/write bit selects the initial output level
of the TCHx pin once PWM, input capture, or output compare
operation is enabled. See Table 12-2. Reset clears the MSxA bit.
1 = Initial output level low
0 = Initial output level high
NOTE: Before changing a channel function by writ ing to the MS xB or MS xA bit,
set the TSTOP and TRST bits in the TIMB stat us and control register